Page 5 - Shimadzu ICPE-9800 Series
P. 5
Chemicals/ Stable injection of organic solvent samples
and high-salt samples
Petrochemicals User-friendly software
Reduced operating costs
In the chemical field, ICP-AES is used for a broad range of analysis stable system able to reliably accept the injection of a broad variety
in order to manage trace amounts of hazardous metals in the of samples, regardless of the type of solvent (aqueous/organic) or
manufacturing process, manage additive elements essential to the the presence of matrices. It is also important to simplify processes
functionality of a product, and manage the environment of the and reduce costs, which enhances the productivity of daily quality
entire factory. Therefore, it is desirable to have a robust, highly control work.
With the ICPE-9800 Series
• The vertical orientation of the torch, which reduces memory effects, ensures 1.20
stable analysis results even for samples with high concentrations of acids or 1.00
salts, or for a variety of organic solvents. 0.80 Ca
• Optimal options for introducing sample with high concentrations of salts, Relative Concentration 0.60 Mg
Mo
organic solvents and hydro uoric acids are prepared. P
• With greatly enhanced usability, the latest software (ICPEsolution) makes 0.40 Zn
everyday analysis even easier and simpler. 0.20
0.00
• Shimadzu's proprietary features (Eco mode, Mini-torch system, and Vacuum 0 20 40 60 80 100 120 140 160180
spectrometer) result in greatly reduced consumption of argon gas.* Elapsed Time (min)
ICPE-9800 guarantees operation with argon gas 99.95% purity. Stability in Continuous 3-Hour Measurement (engine oil)
Using industrial argon gas with lower price makes greatly cost reduction.
* In comparison with purge-type instrument
Metals/Mining/ Easy to check for interference
from matrix components
Electrical and Electronic High accuracy
Long-term performance stability
In fields related to metals and electrical/electronics, ICP-AES is sometimes complicated, high matrix samples. In such cases, it is
primarily utilized for quality control of materials. The demand is for important to avoid interference in order to obtain reliable analysis
high-accuracy analysis and long-term stability. Additionally, with results.
minerals and electronic waste materials, for example, there are
With the ICPE-9800 Series
• Obtain accurate measurement values, even when analyzing complicated 1.2
materials, using the data acquired for all wavelengths, plus a comprehensive
wavelength database that includes interference data. 1.0
• Achieve the highest level of reproducibility and long-term stability due to the 0.8
instrument's proprietary high-frequency power source, a sample injection
system that leaves no memory effects, and a robust optical system. Concentration (mg/L) 0.6
• The axial view unit can be removed, and the system can be used exclusively for Ag As B Ba Ca Cd
radial view. 0.4 Co Cr Cu Fe Hg Mg
0.2
Mn Na Ni Pb Zn
0.0
0.0 100 200 300 400 500
Time (min)
Stability in Continuous 9-Hour Measurements (Aqueous)
1 mg/L Solution of Each Element
Continuous 9-Hour Measurements with Axial View
ICPE-9800 Series
Simultaneous ICP Atomic Emission Spectrometers 5