Page 3 - Shimadzu ICPE-9800 Series
P. 3

Food Products/                     Enhanced throughput
                                                  Optimal methods
               Agriculture                        Reduced operating costs


            Regulations addressing hazardous elements have become increasingly   support a balanced diet and an individual's health. In the area of
            stringent, as the demand grows for food safety. Moreover, labeling   food products, it has become increasingly important for analytical
            that lists the nutritional content of foods, in accordance with de ned   instruments to ef ciently produce highly reliable data over a broad
            nutrition labeling standards, is now mandatory in many places. Such   range of concentrations, whether the targets are trace hazardous
            labeling generally includes minerals and other components that   elements or highly concentrated elements such as minerals.

            With the ICPE-9800 Series
              • Achieves a broad dynamic range from ppb to percent order due to axial and radial views. This allows comprehensive analysis of a broad
               range of concentrations all at once, thus enhancing throughput.
              • The all-wavelengths acquisition system detects the in uence of the matrix, and always offers the optimal method. Accurate analysis values
               can be acquired at great speed.
              • Shimadzu's proprietary features (Eco mode, Mini-torch system, and Vacuum spectrometer) result in greatly reduced consumption of argon
               gas and less than half of total running cost.*
               * In comparison with purge-type instrument

            Simultaneous analysis of elements in cheese and drinking water
                       Element           Pb        Cd       Fe       Mn        K       Mg        Na       Ca
              Cheese decomposition solution  mg/L  < 0.001  < 0.0003  0.04  0.007  23.0  11.7    469      337
                    View orientation     Axial    Axial    Axial     Axial   Radial   Radial    Radial   Radial
              Drinking water     mg/L   < 0.001  < 0.0003  0.06     0.005     0.70     2.95      4.48     12.5
                    View orientation     Axial    Axial    Axial     Axial    Axial    Axial    Radial   Radial






               Environment/                       Reduced analysis times
                                                  Superior stability over long periods
               Tap Water/Waste Water              High sensitivity


            The environmental  eld requires robust, high-sensitivity analysis   safety of the water supply and protect the environment. Moreover, in
            capable of complying with regulations in order to always meet the   laboratories where more than 100 samples are processed per day,
            stringent target values that have been established to assure the   increasing the throughput and saving energy are issues of concern.

            With the ICPE-9800 Series
              • Offering the highest level of robustness, the sample injection system (vertical torch orientation) is designed to minimize torch clogging and
               memory effects. Even with boron, which tends to produce memory effects, measurements can be repeated with short rinse times, thus
               resulting in a shorter analysis time.
              • The axial view has been optimized in order to provide the utmost in sensitivity.
              • Realize an even higher level of sensitivity by making use of the optional ultrasonic nebulizer or a hydride generator.

                      0.3                                     Conventional (horizontal torch orientation)
                     Boron Concentration (mg/L)  0.15  Vertical Torch  Horizontal Torch Orientation   ICPE-9800 Series  B Rinse time  2nd sample measured
                      0.25
                      0.2
                                                                  1st sample measured
                                 (conventional con guration)
                          Orientation
                      0.1
                      0.05 A
                      0.00
                        0     2  B  4     6     8                 1st sample measured  A  2nd sample measured  Fast!
                                 Rinse Time (min)
                            Boron Memory Test Data
                Blank sample measured after injecting 100 mg/L boron for about 2 minutes

                                                                                            ICPE-9800 Series
                                                                                          Simultaneous ICP Atomic Emission Spectrometers  3
   1   2   3   4   5   6   7   8