Page 10 - Shimadzu GC-2025
P. 10

Shimadzu Gas Chromatography Workstation

            GCsolution  Ver.2 (Windows7)



            GCsolution workstation software improves productivity, reliability,                                                       Easy Operation “Assistant Bar” and
            and operability with the "Assistant Bar" and "Data Explorer"
            functions. Moreover, the high-level operating environment                                                                 “Data Explorer”
            supports GLP/GMP compliance for pharmaceutical and environ-                                                                • The “Assistant Bar” allows navigation operation from analysis start
            ment applications.
                                                                                                                                        to post-run analysis using simple icons.
                                                                                                                                       • « Data Explorer » classifies and displays files.
            Easy Operation for Improved Productivity           Supports GLP/GMP
            ˔ Common operation system in LabSolutions series has  ˔ For improved data reliability, GCsolution supports
                                                                                                                                                                                         Assistant Bar
                been adopted, for more intuitive operation and a      GLP/GMP with its user-management, self-diagnosis,                                                                  Data Explorer
                shorter learning curve.                            and audit trail functions
            ˔ The software features an enhanced manipulation   ˔ An optional function for supporting Part11 is available.
                function for improved operability and functionality.
                                                                                                                                      “Batch Table Wizard” Makes
                                                               Network Support                                                        Continuous Analysis Easier
            Enhanced Basic Functions                           ˔ A network environment for remote access and data                      • Analysis of many samples continuously with the Batch Table
            ˔ Control and data processing function enable use of up      analysis can be effectively implemented.                       Wizard.
                to 4 GC systems.                               ˔ Sharing various files and the uniform management of                   • Using the Wizard instructions, simply enter the necessary items for
                Corresponding models: GC-2025, GC-2010 Plus,       data are possible using "CLASS-Agent".
                GC-2010, GC-2014, GC-17A, GC-1700, and GC-14A/B                                                                         easy batch table creation.
            ˔ The data processing functions in Chromatopac and
                CLASS-GC10 have been implemented.              Customizing
            ˔ The identification, quantitation and data comparison  ˔ An easier custom-designed operating environment using
                functions have been enhanced.                      the OLE automation function can be constructed.                    Editing Reports « Report creation function »
            ˔ The data station offers flexible report options and the
                                                                                                                                       • Easily construct reports.
                summary report can be output.                  OS
                                                               ˔ An Windows 7 Professional / Windows XP Professional /                 • Paste and edit items such as chromatograms and peak tables
                                                                                                                                        without any limitation.
                                                                   Windows Vista Business
                                                                                                                                       • Completed report formats can be saved as templates.
                                                                                                                                       • “LabSolutions”  is equipped with a PDF output function as
                                                                                                                                        standard. Save analysis reports as PDF files to promote paperless
                                                                                                                                        operation.

                                                                                                                                      Specifications of GCsolution Ver.2


                                                                                                                                      ˙Software                                          ˙Reporting
                                                                                                                                        Corresponds with Windows 7 Professional / Windows XP Professional / Windows Vista Business  Over 10 items such as Sample information, Method, Chromatogram, Peak table,
                                                                                                                                        32Bit application (correspondent with long file name)  Calibration curve, Grouping result, Figures, Texts, etc. Corresponds with OLE object,
                                                                                                                                        Graphical U/I (Assistant Bar etc.)                 Customized layouts, Preview function, Summary report.
                                                                                                                                      ˙Controllable equipment                            ˙Files
                                                                                                                                        GC-2025, GC-2010 Plus, GC-2010, GC-2014, GC-17A, GC-1700, GC-14A/B,  Data explorer for file controlling, All-in-one file system, File transforming function
                                                                                                                                        AOC-20i/s, TurboMatrix*, AOC-5000*.                (CLASS-GC10 form, AIA ANDI form, Text form), File explorer function, Template function
                                                                                                                                        Max 4 GCs (9 detectors) can be controlled simultaneously .  ˙H/W
                                                                                                                                        Max 4 detectors (GC-2010) or 2 detectors (GC except for GC-2010) can control dual injection.  GC auto stop/start functions, System check (GC self-check) function, Status log function
                                                                                                                                        * Optional s/w is necessary to control Turbo matrix, AOC-5000.
                                                                                                                                      ˙Data acquisition                                  ˙GLP/GMP
                                                                                                                                                                                           Audit trail function, Software validation, Security function, Part 11 function (Optional)
                                                                                                                                        Minimum sampling time 4ms, Snapshot function, Single/Batch analysis control, Batch table
                                                                                                                                        wizard, Additional/cutting-in analysis, Analysis time extension, Auto data file creation   ˙Available network
                                                                                                                                        function, QA/QC (statistical calculation) function, Auto batch stopping function, User   Post-run application s/w (Second use license s/w, optional, GC-LAN connectable (Optional)
                                                                                                                                        program starting function, Correspondent with pre-run program, Correspondent with OLE   ˙Other
                                                                                                                                        automation (batch analysis etc.)                   Maintenance guide (GC-2025, GC-2010 Plus, GC-2010, GC-2014, GC-17A/1700,
                                                                                                                                      ˙Data processing                                     GC-14A/B, AOC-20i)
                                                                                                                                        Undulation processing function, manipulation function, identification function (with multi
                                                                                                                                        relative retention time and grouping), quantitative function (least squares method,
                                                                                                                                        modified least squares method, internal standard method, external standard method,
                                                                                                                                        standard additional method, retention index calculation, manual response factor entering),
                                                                                                                                        weighted and linear calibration (16 levels x 10 points), Manual calibration curve creation,
                                                                                                                                        column performance calculation, data comparison function
                                                                                                                                                                                                                               GC-2025
      10                                                                                                                                                                                                               Energy Saving Capillary Gas Chromatograph  11
   5   6   7   8   9   10   11   12