Page 5 - Shimadzu GC-2010 Pro
P. 5

Flexible lineup for various analysis





 Two analytical lines can be operated simultaneously for different applications  Achieving excellent reproducibility



            All units including the column oven, flow controller and sample
            injection unit are comprehensively optimized at the design stage
            to achieve world-class repeatability of peak area and peak height.
 High performance injector /  High precision gas control
 high sensitivity detector  The injector and detector gas is controlled   The large vaporization capacity ensures excellent repeatability,
 Simultaneously install up to two analytical lines and   by the high-performance modular   even when using solvents that are highly volatile upon injection,
 up to three detectors.  electronic flow controller.  such as acetone. Long-term stability of retention time is realized by
 (Consult separately for the quantity of units that can be   the new room compensation technology built into the advanced
 carried simultaneously.)
            flow controller (AFC).





                                                                       Analysis of Grob Test Mixture (Solvent: acetone, each 100 ppm)

                                       1         2        3         4        5        Mean   Standard deviation  C.V.%
                1  n-decane          23479     23467     23371     23416    23415    23429.8    43.8058     0.1870
                2  n-octyl alcohol   22324     22292     22201     22284    22164    22252.9   67.2148    0.3020
                3  n-undecane        24013     24046     23919     23967    24041    23997.2   53.6469    0.2236
                4  2,6-dimethylaniline  29692   29653    29500     29593    29645    29616.6   74.0909    0.2502
                5  Methyl n-nonanoate  20614   20552     20512     20529    20609    20563.3   46.5207    0.2262
                6  Methyl n-caprate  21470     21487     21493     21506    21469    21484.8   15.9908    0.0744
                7  Dicyclohexylamine  28044    28124     28000     28049    28119    28067.3   53.1637    0.1894
                8  Methyl laurate    22750     22739     22726     22761    22822    22759.5   37.2898    0.1638
                                                      Peak area reproducibility



            High-speed analysis


            High-speed analysis with narrow bore capillary columns reduces analysis time and improves sample throughput. GC-2010 Pro has
            excellent flow and pressure control system, which can meet the requirements of rapid analysis with conventional configuration and
            effectively improve the analysis efficiency.

                                                                             DB-WAX
                                                                             0.25mm×60m, 0.25µm
                                                                             ( He 25cm/s )
                                                                                  Analysis time with
                                                                                  conventional conditions
                                                                                  60 minutes
              6                     12

                                                      Rtx-WAX
                                                      0.1mm×20m, 0.1µm
                                                      ( He 25cm/s )
                                                      20 minutes
 Column oven  Big display                                  Analysis time reduced by GC-2010 Pro
 Faster heating accelerates chromatographic   Big display for easy operation and  3  5
 separation and fast cooling reduces GC run time.  providing all information at a glance
                                         High-speed analysis of coffee flavoring


                                                                                               GC-2010 Pro
 4                                                                                                 Capillary Gas Chromatograph  5
   1   2   3   4   5   6   7   8   9   10