Page 10 - Shimadzu GC-2010 Pro
P. 10
Small and high-sensitivity detector series
Options enhancing scalability
The full range of high-sensitivity detectors supports a wide variety of application analyses.
Each detector is equipped with an advanced pressure controller (APC) that digitally sets the gas parameters of each
detector. To ensure secure use of hydrogen the connector joints have reverse threads to prevent incorrect pipe connec-
tions (FID, FPD, FTD).
Flame ionization detector For analysis of Electron capture detector For analysis of
all organic electrophilic
FID compounds ECD compounds
• High-sensitivity has been achieved by thorough cleaning of detector • For analysis of electrophilic compounds and also for high sensitivity
gas lines and the latest noise-reduction technology. detection of organohalogen compounds, metallo-organic com-
Simultaneously install up to three injection units and up to three detectors * • Automatic ignition, re-ignition and flame extinguishing functions pounds and compounds with C=O double bond.
• Feedback function reduces gas supply pressure to zero when the • By thoroughly simulating the gas flow path inside the ECD detection
hydrogen flame is extinguished. cell, a gas flow path and the detection structure (Contact Free
• Hydrogen connector joints have reverse threads to prevent incorrect technology) are developed to minimize the contact between the
Select from three injection units and five detector types to pipe connections. samples flowing from the chromatographic column and the collector
suit the needs of your analysis. When using LabSolutions, 1 ・1,1,1-trichloroethane S/N ≧ 5 1:1,1-Dichloroethene and the nickel wire source, thus significantly improving the
2:1,1,1-Trichloroethane
・S/N of All peaks ≧ 3 durability of ECD detection cell.
three kinds of plotter can be used for simultaneous 2 4 3:Carbontetrachloride 1:α-BHC
4:Benzene
detection. Options such as injection units, detectors and 5 5:1,2-Dichloroethane 2 3 6 8 9 10 2:β-AAA
3:Hexachlorobenzene
1 4 5 7 11 12 13 14 4:γ-BHC
autoinjectors can easily be retrofitted. 3 15 5:Heptachlor
6:Dichloropropionic acid
*The number of parts installed simultaneously depends on the 8 GC-2010 Pro 顶部 2.5 5.0 7.5 10.0 12.5 min 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 min 7:Heptachlor-exo-epoxide
4
type of injection unit and detector. Analysis of aqueous solution of medicine residual solvent Analysis of 10ppb of organochlorine pesticides 8:Heptachlor epoxide A+
oxychlordane isomer
USP467 Class1 ProcedureA
*Only two analytical lines could be running simultaneously. 7 For injection unit 3 9:Chlordane-cis
10:Chlordane-trans
6 For detector 2 Thermal conductivity detector For analysis of 11:Dieldrin
12:Endrin
inorganic gases and
5 1 concentrated organic 13:o, p'-DDT
14:p, p'-DDT
TCD compounds 15:Dicofol
• Microvolume cell for sharper peaks Contact-free Technology
Top of GC-2010 Pro • Analysis is not easily affected by the temperature changes
within column oven For analysis of
High-performance injection unit series Flame thermionic detector organo nitrogen
and phosphorus
For analysis of FTD compounds
Flame photometric detector organic phosphorus
and sulfur
In order to obtain good data, it is necessary to select an appropriate injection method according to the analysis purpose and sample. FPD compounds • For analysis of organo nitrogen and phosphorus compounds, such as
GC-2010 Pro can select the most suitable injection method from three injection units. residual pesticides.
• No tools needed for collector replacement.
• For analysis of pesticide residues, odor components, phosphorous • Alkali source regeneration kit (option) reduces operational costs.
compounds, sulfur compounds and organo-tin compounds. • Hydrogen connector fittings have reverse threads to prevent pipe
Split/splitless injector Direct injection unit • The dual-focus system achieves high sensitivity. connections.
• No tools required for replacement of interference filters with high
SPL WBI daily maintenance frequency.
• Injection unit used for split/splitless injection of capillary column. • Used for full injection of wide bore capillary columns above
• Standard configuration, namely, AFC with high performance, 0.45mm.
supports high-speed GC with narrow bore capillary columns. • Septum purge flow channel prevents solvent tailing.
• Gas saver function reduces split gas consumption. • Uses the same glass inserts as splitless analysis to simplify use. Automatic injection system
• Permits high-pressure injection mode. (Patented)
• The purge flow can be set and changed to achieve more efficient
sample purge and prevent cross contamination.
Automatic liquid injection system for GC
On-column/programmed temperature vaporization injector
AOC -20 series
™
OCI/PTV
• Easy to install and remove.
• Temperature programmable Injector • Configured for either cool, on-column injector (OCI) or programmed • AOC-20s can support analysis of up to 150 samples (1.5mL sample
The sample is injected at a low temperature and gasified by temperature vaporization (PTV) injection mode. bottles).
programmed heating of the injection port. This was recovery of • Uses inert quartz PTV inserts. • A dual injection system can be configured with a combination of
thermolabile components can be improved. OCI is suitable for • An optional OCI insert allows connecting a narrow-bore capillary two AOC-20i injectors. Two-line simultaneous injection doubles the
samples with a wide boiling point range. column directly to the injector without a 0.53mm pre-column. (No sample throughput to improve productivity.
need to compress the connecting device)
GC-2010 Pro
10 Capillary Gas Chromatograph 11