Page 10 - Shimadzu GC-2010 Pro
P. 10

Small and high-sensitivity detector series
            Options enhancing scalability


                                                                                                                                      The full range of high-sensitivity detectors supports a wide variety of application analyses.
                                                                                                                                            Each detector is equipped with an advanced pressure controller (APC) that digitally sets the gas parameters of each
                                                                                                                                      detector. To ensure secure use of hydrogen the connector joints have reverse threads to prevent incorrect pipe connec-
                                                                                                                                      tions (FID, FPD, FTD).


                                                                                                                                      Flame ionization detector             For analysis of   Electron capture detector       For analysis of
                                                                                                                                                                             all organic                                       electrophilic
                                                                                                                                             FID                            compounds            ECD                           compounds

                                                                                                                                       •  High-sensitivity has been achieved by thorough cleaning of detector   •  For analysis of electrophilic compounds and also for high sensitivity
                                                                                                                                        gas lines and the latest noise-reduction technology.  detection of organohalogen compounds, metallo-organic com-
            Simultaneously install up to three injection units and up to three detectors *                                             •  Automatic ignition, re-ignition and flame extinguishing functions  pounds and compounds with C=O double bond.
                                                                                                                                       •  Feedback function reduces gas supply pressure to zero when the   •  By thoroughly simulating the gas flow path inside the ECD detection
                                                                                                                                        hydrogen flame is extinguished.                     cell, a gas flow path and the detection structure (Contact Free
                                                                                                                                       •  Hydrogen connector joints have reverse threads to prevent incorrect   technology) are developed to minimize the contact between the
            Select from three injection units and five detector types to                                                                 pipe connections.                                  samples flowing from the chromatographic column and the collector
            suit the needs of your analysis. When using LabSolutions,                                                                             1  ・1,1,1-trichloroethane S/N ≧ 5  1:1,1-Dichloroethene  and the nickel wire source, thus significantly improving the
                                                                                                                                                                        2:1,1,1-Trichloroethane
                                                                                                                                                    ・S/N of All peaks ≧ 3                  durability of ECD detection cell.
            three kinds of plotter can be used for simultaneous                                                                                                2  4     3:Carbontetrachloride                              1:α-BHC
                                                                                                                                                                        4:Benzene
            detection. Options such as injection units, detectors and                                                                                              5    5:1,2-Dichloroethane   2 3          6  8  9 10     2:β-AAA
                                                                                                                                                                                                                           3:Hexachlorobenzene
                                                                                                                                                                                              1  4   5  7    11  12  13  14  4:γ-BHC
            autoinjectors can easily be retrofitted.                                                                                                             3                                                    15    5:Heptachlor
                                                                                                                                                                                                                           6:Dichloropropionic acid

            *The number of parts installed simultaneously depends on the   8     GC-2010 Pro 顶部                                                2.5  5.0  7.5  10.0  12.5  min              7.0  8.0  9.0  10.0  11.0  12.0  13.0  14.0  min  7:Heptachlor-exo-epoxide
                                                                                           4
            type of injection unit and detector.                                                                                        Analysis of aqueous solution of medicine residual solvent   Analysis of 10ppb of organochlorine pesticides  8:Heptachlor epoxide A+
                                                                                                                                                                                                                                 oxychlordane isomer
                                                                                                                                                 USP467 Class1 ProcedureA
            *Only two analytical lines could be running simultaneously.    7     For injection unit  3                                                                                                                     9:Chlordane-cis
                                                                                                                                                                                                                           10:Chlordane-trans
                                                                           6            For detector  2                                Thermal conductivity detector        For analysis of                                11:Dieldrin
                                                                                                                                                                                                                           12:Endrin
                                                                                                                                                                          inorganic gases and
                                                                           5               1                                                                              concentrated organic                             13:o, p'-DDT
                                                                                                                                                                                                                           14:p, p'-DDT
                                                                                                                                            TCD                             compounds                                      15:Dicofol
                                                                                                                                       •  Microvolume cell for sharper peaks                Contact-free Technology
                                                                                 Top of GC-2010 Pro                                    •  Analysis is not easily affected by the temperature changes
                                                                                                                                        within column oven                                                                    For analysis of
            High-performance injection unit series                                                                                                                                       Flame thermionic detector            organo nitrogen
                                                                                                                                                                                                                              and phosphorus
                                                                                                                                                                            For analysis of     FTD                            compounds
                                                                                                                                      Flame photometric detector          organic phosphorus
                                                                                                                                                                             and sulfur
            In order to obtain good data, it is necessary to select an appropriate injection method according to the analysis purpose and sample.  FPD                      compounds     •  For analysis of organo nitrogen and phosphorus compounds, such as
            GC-2010 Pro can select the most suitable injection method from three injection units.                                                                                          residual pesticides.
                                                                                                                                                                                          •  No tools needed for collector replacement.
                                                                                                                                       •  For analysis of pesticide residues, odor components, phosphorous   •  Alkali source regeneration kit (option) reduces operational costs.
                                                                                                                                        compounds, sulfur compounds and organo-tin compounds.  •  Hydrogen connector fittings have reverse threads to prevent pipe
            Split/splitless injector                           Direct injection unit                                                   •  The dual-focus system achieves high sensitivity.  connections.
                                                                                                                                       •  No tools required for replacement of interference filters with high
                   SPL                                             WBI                                                                  daily maintenance frequency.
            •   Injection unit used for split/splitless injection of capillary column.  •  Used for full injection of wide bore capillary columns above
            •   Standard configuration, namely, AFC with high performance,   0.45mm.
             supports high-speed GC with narrow bore capillary columns.  •   Septum purge flow channel prevents solvent tailing.
            •   Gas saver function reduces split gas consumption.  •   Uses the same glass inserts as splitless analysis to simplify use.   Automatic injection system
            •   Permits high-pressure injection mode.            (Patented)
            •   The purge flow can be set and changed to achieve more efficient
             sample purge and prevent cross contamination.
                                                                                                                                       Automatic liquid injection system for GC
            On-column/programmed temperature vaporization injector
                                                                                                                                        AOC -20 series
                                                                                                                                             ™
                 OCI/PTV
                                                                                                                                       •  Easy to install and remove.
             •   Temperature programmable Injector              •   Configured for either cool, on-column injector (OCI) or programmed   •  AOC-20s can support analysis of up to 150 samples (1.5mL sample
              The sample is injected at a low temperature and gasified by   temperature vaporization (PTV) injection mode.               bottles).
              programmed heating of the injection port. This was recovery of   •   Uses inert quartz PTV inserts.                      •  A dual injection system can be configured with a combination of
              thermolabile components can be improved. OCI is suitable for   •   An optional OCI insert allows connecting a narrow-bore capillary   two AOC-20i injectors. Two-line simultaneous injection doubles the
              samples with a wide boiling point range.           column directly to the injector without a 0.53mm pre-column. (No       sample throughput to improve productivity.
                                                                 need to compress the connecting device)
                                                                                                                                                                                                                         GC-2010 Pro
      10                                                                                                                                                                                                                     Capillary Gas Chromatograph  11
   5   6   7   8   9   10   11   12   13   14   15