Page 4 - Shimadzu GC-2010 Pro
P. 4

Flexible lineup for various analysis





            Two analytical lines can be operated simultaneously for different applications                                            Achieving excellent reproducibility



                                                                                                                                      All units including the column oven, flow controller and sample
                                                                                                                                      injection unit are comprehensively optimized at the design stage
                                                                                                                                      to achieve world-class repeatability of peak area and peak height.
                                     High performance injector /                  High precision gas control
                                     high sensitivity detector                    The injector and detector gas is controlled         The large vaporization capacity ensures excellent repeatability,
                                     Simultaneously install up to two analytical lines and   by the high-performance modular          even when using solvents that are highly volatile upon injection,
                                     up to three detectors.                       electronic flow controller.                          such as acetone. Long-term stability of retention time is realized by
                                     (Consult separately for the quantity of units that can be                                        the new room compensation technology built into the advanced
                                     carried simultaneously.)
                                                                                                                                      flow controller (AFC).





                                                                                                                                                                                                 Analysis of Grob Test Mixture (Solvent: acetone, each 100 ppm)

                                                                                                                                                                 1         2        3         4        5        Mean   Standard deviation  C.V.%
                                                                                                                                          1  n-decane          23479     23467     23371    23416     23415    23429.8    43.8058     0.1870
                                                                                                                                          2  n-octyl alcohol   22324     22292     22201    22284     22164    22252.9   67.2148    0.3020
                                                                                                                                          3  n-undecane        24013     24046     23919    23967     24041    23997.2   53.6469    0.2236
                                                                                                                                          4  2,6-dimethylaniline  29692   29653    29500    29593     29645    29616.6   74.0909    0.2502
                                                                                                                                          5  Methyl n-nonanoate  20614   20552     20512    20529     20609    20563.3   46.5207    0.2262
                                                                                                                                          6  Methyl n-caprate  21470     21487     21493    21506     21469    21484.8   15.9908    0.0744
                                                                                                                                          7  Dicyclohexylamine  28044    28124     28000    28049     28119    28067.3   53.1637    0.1894
                                                                                                                                          8  Methyl laurate    22750     22739     22726    22761     22822    22759.5   37.2898    0.1638
                                                                                                                                                                                Peak area reproducibility



                                                                                                                                      High-speed analysis


                                                                                                                                      High-speed analysis with narrow bore capillary columns reduces analysis time and improves sample throughput. GC-2010 Pro has
                                                                                                                                      excellent flow and pressure control system, which can meet the requirements of rapid analysis with conventional configuration and
                                                                                                                                      effectively improve the analysis efficiency.

                                                                                                                                                                                                      DB-WAX
                                                                                                                                                                                                      0.25mm×60m, 0.25µm
                                                                                                                                                                                                      ( He 25cm/s )
                                                                                                                                                                                                            Analysis time with
                                                                                                                                                                                                            conventional conditions
                                                                                                                                                                                                            60 minutes
                                                                                                                                        6                     12

                                                                                                                                                                                Rtx-WAX
                                                                                                                                                                                0.1mm×20m, 0.1µm
                                                                                                                                                                                ( He 25cm/s )
                                                                                                                                                                                20 minutes
                                     Column oven                               Big display                                                                                           Analysis time reduced by GC-2010 Pro
                                     Faster heating accelerates chromatographic   Big display for easy operation and                    3                     5
                                     separation and fast cooling reduces GC run time.  providing all information at a glance
                                                                                                                                                                   High-speed analysis of coffee flavoring


                                                                                                                                                                                                                         GC-2010 Pro
      4                                                                                                                                                                                                                      Capillary Gas Chromatograph  5
   1   2   3   4   5   6   7   8   9