Page 6 - Shimadzu EDX-LE Plus
P. 6

Screening Software Features                                                  The instrument


            A single click in the "Screening Analysis" window automatically               automatically                               A Variety of Functions To Make Screening Easier
            performs everything from measurement to the display of results,           makes the dif cult
            in accordance with your pre-registered analysis conditions.                                                               Simple Screening Setup                               Improved Security for Software Operations
                                                                                            decisions.                                Screening conditions can be customized easily according to
                                                                                                                                      the control system.
            All steps, from judgment of the main components                                                                           Changing Threshold Values                            Condition Protection Function
            to the selection of conditions, are automated                                                                             Threshold values can be set for each material or element.   Restrictions can be speci ed for screening conditions and
                                                                                                                                      The screening judgment method can also be changed in   various other settings.
            Automatic Calibration Curve Selection Function                                                                            accordance with the input method used for threshold
                                                                                                                                      values. Furthermore, the user can refer to lower threshold
             Unknown             Several user-determined steps                                                                        limits for each material to aid in setting their own threshold
             sample                                                                                                                   values.
                                 If the user cannot determine the main component, selecting the optimal calibration curve
                                 is dif cult.


                                                               Brass?
                                                         Metal  Al alloy?
                                                               Solder?        Decide
                                   Is this                                    analysis conditions
                        Conventionally  metal?   Condition                    (calibration curve)
                         Conventionally
                                                 settings
                                   Plastic?                                   depending on
                                                         Plastic  PVC?        main component.
                                                                 PE?

                                                                                                     Results                          Changing Judgment Character Strings
                                                                                                                                      The user can specify the character strings displayed for
                                                                                                                                      judgments in analysis results, used to indicate whether they
                                                                                                                                      are below the threshold value, in the gray zone, or above
                                                                                                                                      the threshold value.
                                    Start                                                                                             Changing the Report Template
                                                  Requires no user decisions
                                    measurement   Requires no user decisions
                         EDX-LE Plus  with a single                                                                                   The style used for reports can be changed. The standard
                         EDX-LE Plus
                                    click!        EDX-LE Plus automatically determines the main component,                            templates provided can be selected.
                                                  selects the optimal calibration curve, and performs the measurement.

                                                                                                                                      A Variety of Functions To Minimize Instrument Maintenance Requirements
                                                                                                                                      Automatic X-ray Tube Ageing Function
                                                                                                                                      If the instrument has not been used for a long time, the X-ray tube must be aged
            Automatic Measurement Time Reduction                                Concentration                                         when it is restarted. To prevent malfunction, this process has been automated.

            This function automatically switches to the next analysis channel if a controlled   Above control standard
            substance clearly has a high or low concentration, making evaluation possible while
                                                                                  Standard value
            measurement is underway. This achieves more ef cient screening analysis.        Gray zone

                 Clearly above the control standard, so measurement is cut off.                                                       Detector Does Not Require Liquid Nitrogen
                 Gray zone. Measurement proceeds for the set time.                                Below control standard              The EDX-LE Plus is equipped with a detector that does not need to be cooled with
                 Clearly below the control standard, so measurement is cut off.                                                       liquid nitrogen, providing signi cantly reduced operating costs.

                                                                                                                                                                                                                          EDX-LE Plus
      6                                                                                                                                                                                                             Energy Dispersive X-ray Fluorescence Spectrometer  7