Page 8 - Shimadzu DPiMS QT
P. 8

Specifications                                                                                           DPiMS QT

                               DPiMS QT controller    Control of the DPiMS QT unit (Installed in the mass spectrometer)
                                                      Probe Voltage: ±5 kV max. (set voltage)
                                                      Probe Stroke: 46.30 mm max.
                Hardware                              Number of Extraction Cycles: 300 max.
                               DPiMS QT unit
                                                      Probe Speed: 300 mm/sec max.
                                                      Probe Acceleration: 1 G max.
                                                      Probe Stop Time: 60,000 msec max.
                               PESI MS Solution       Used to select analytical conditions and start analysis
                Software       LabSolutions           Used to specify MS analysis method settings and analyze data
                               (Probe Control Software)  Used to specify probe control method settings
                               Probe                  Set of 10 or 50 pcs.
                Consumables
                               Plate                  Plates available for both liquid and biological samples (set of 100 pcs. each)
                               Room temperature       18 to 28 °C
                Installation   Humidity               20 to 70 % (No-condensing and no-discharge due to static electricity)
                requirements*                         Should be installed in an environment without dust, oscillation,
                               Others
                                                      electromagnetic noise, corrosive gas and electromagnetic interference.

               *Equivalent to the installation requirement of mass spectrometer.










































               DPiMS and LabSolutions are trademarks of Shimadzu Corporation or its affiliated companies in Japan and/or other countries.





                                                 For Research Use Only. Not for use in diagnostic procedures.
                                                 This publication may contain references to products that are not available in your country. Please contact us to check the availability of
                                                 these products in your country.
                                                 Company names, products/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation,
                                                 its subsidiaries or its affiliates, whether or not they are used with trademark symbol “TM” or “®”.
                                                 Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether
                                                 or not they are used with trademark symbol “TM” or “®”.
                                                 Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.
         www.shimadzu.com/an/                    The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice.
                                                 Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.
                                                                  © Shimadzu Corporation, 2021 / First Edition: August 2021, 3655-06102-PDFNS, C146-E440
   3   4   5   6   7   8