Page 4 - Shimadzu BioSpec-nano
P. 4

Drop-and-Start Analysis                      [1 µL / 2 µL samples can be measured.]  Note2)                               Automatic Optical Pathlength Setting & Automatic Wiping


                    Just drop the sample onto the target and click the button. That's all there is to analysis. The instrument will perform everything else for   From setting the optical pathlength to measurement to wiping away the sample, it’s all automatic.
                    you – sample mounting, measurement and wiping. Liquid-contact parts no longer need to be wiped with a cloth.              Tedious operations, like raising and lowering the arm to set the pathlength and wiping off the sample with a piece of cloth, are no longer
                                                                                                                                              required. There is no need to worry about whether the sample has been thoroughly wiped away, or whether the measurement site might
                                                                                                                                              become scratched.
                     1. Drop the sample


                      Sample volume required for
                      measurements are :
                      1 µL for pathlength 0.2 mm
                      2 µL for pathlength 0.7 mm


                                                                                                                                                                                          Depositing sample
                     2. Outstanding analysis range &
                         measurement reproducibility


                      The optimum pathlength for the
                      sample concentration can be selected
                                                                                                                                                           Upper window
                      using the instrument lever.
                                                                                                                                                                                Target
                                                                                                                                                              Lowering window and measurement              Sample wiping and raising window

                     3. Start measurement                                                          Automatic sample wiping
                                                                                                   allows the analyst to
                                                                                                   deposit the next
                      Click the [start] button to start sample                                                                                Low Carryover Achieved with Automatic Wiping Feature
                                                                                                   measurement sample while
                      measurement.
                                                                                                   the current sample is being
                      You will find using the [start] button on
                                                                                                   measured without having                    The automatic wiping function of the BioSpec-nano greatly   measurements. In order to determine the level of carryover from
                      the instrument handy when performing                                         to put down the pipette.                   minimizes sample carryover from one measurement to the next.   the measured DNA sample, measurement of the next blank was
                      analyses with gloves on.        Button in software                                                                      Below are the results of alternate measurement of a double   conducted without replacing the wiper during the analyses. The
                                                      window                                       Measurement is easy even
                                                                                                   when there are many                        stranded DNA sample and a blank (TE buffer), each measured 60   results indicated that carryover Note 4)  was extremely low, averaging a
                                                                                                   samples.                                   times with automatic one-time wiping Note 3)  between   mere 0.13%.
                                                                  Instrument [start] button
                                                                                                                                              Note 3) Automatic wiping following measurement can be set to a maximum of 5 times. Normally, wiping just once is sufficient to obtain good
                                                                                                                                                           results, however, wiping 3 times is recommended for samples having high viscosity, such as protein samples.
                     4. Check the analysis results                                                                                            Note 4) Carryover (%) = (calculated DNA concentration when measuring TE buffer / concentration of DNA measured immediately before) x 100.


                      Analysis results are automatically
                      displayed after measurement ends.                                                                                        Measurement Values from 60 Alternate Measurements Each of Double Stranded DNA Sample and Blank (TE Buffer)
                      A series of samples can be analyzed
                      while confirming spectra in the
                      Detailed View Mode.                                                                                                                    15


                                                                                                                                                           OD Value  10

                                                                                                                                                             5
                                                                                                                                                             0
                                                                 [Simple Nucleic Acid Quant. - Detailed View Mode]
                                                              [Measurement Sample: Purified dsDNA in Tris-EDTA (TE) buffer]                                    0          20         40          60         80         100        120
                                                                                                                                                                                          Number of Measurements
                    Note 2) When measuring substances like proteins that do not easily form droplets, deposit more than 1 – 2 µL of sample.
                                 The results can be checked using the analysis data judgment feature. (See P. 7)