Page 11 - Kubota - 7000
P. 11
Swinging bucket rotor
S-724 Bucket Code No. Bucket Code No.
(Buckets are optional) 053-5820 053-5840
Max. 3,500 rpm
Max. 2,380 g
Autoclavable *
Please contact our distributor for tube racks and adaptor.
S-2504 S-5004
(Equipped with buckets) (Equipped with buckets and sealing caps)
Max. 4,800 rpm Max. 4,000 rpm
Max. 4,300 g
Max. 3,080 g
Autoclavable * Autoclavable *
7000/6000 Tube Rack
Tube size (mm) Bucket
Rotor Name Nominal Capacity Adaptor
diam. x length Maximum Speed Maximum RCF Code No.
rpm x g Code No.
80 x 1.5/2mL 9.5〜11 x 36〜42 2,290 055-4800
24 x 8mL CPT cell preparation tube *1 13.5〜15.8 x 81〜130 2,310 055-6900
80 x 10mL glass tube 12〜13.8 x 65〜95 2,080 055-4740
48 x 5〜10mL blood collection tube/15mL glass tube *2 12〜16.8 x 72〜110 2,300 055-0880
32 x 15mL conical tube 17 x 121 2,330 055-4780
8 x 50mL glass tube 27〜36.4 x 85〜110 3,500 2,330 053-5820 055-4760
16 x 50mL conical tube 30 x 117 2,330 055-6070
S-724
4 x 100mL glass tube 38〜46.5 x 83〜120 2,330 055-4770
4 x 175/200/225mL conical tube *3,4 61 x 118/61 x 130/61 x 137 2,330 055-4850
250mL 4 *5 60〜62 x 100〜134.4 2,380 055-4850
8x/12x/16x Self-Standing sputum collection tube cap size φ48/φ37/φ31 2,250〜2,300 *6
68 x 5〜7mL thin blood collection tube *7 12〜13.7 x 62〜110 2,300 055-0260
68 x 10mL blood collection tube/15mL glass tube 15〜17.2 x 52〜110 3,500 2,300 053-5840 * 10 ―
28 x 15mL conical tube 17 x 121 2,300 ―
36 x 1.5/2mL 9.5〜11 x 36〜42 4,250 055-1190
28 x 5〜10mL blood collection tube/15mL glass tube *2 12〜17.2 x 72〜110 4,150 055-1140
16 x 15mL conical tube 17 x 121 4,280 055-1160
4 x 50mL glass tube 27〜36.4 x 85〜110 4,150 Equipped 055-1150
S-2504 4 x 50mL conical tube 30 x 117 4,800 4,250 055-1170
*11 4 x 100mL glass tube 38〜46.5 x 113〜120 4,250 with rotor 055-1200
4 x 175/225mL conical tube *8 61 x 118/61 x 137 4,250 *3
4 x 250mL *5 60〜62 x 100〜134.4 4,300 ―
4 x Self-Standing sputum collection tube cap size φ48 4,250 055-1210
72 x 1.5/2mL 9.5〜11 x 36〜42 3,040 055-0770
48 x 5〜10mL blood collection tube/15mL glass tube *2 12〜17.2 x 72〜110 2,970 055-0730
28 x 15mL conical tube 17 x 121 3,060 055-0750
12 x 50mL glass tube 27〜36.4 x 85〜110 2,990 055-0740
12 x 50mL conical tube 30 x 117 3,040 Equipped 055-0760
S-5004 4,000
4 x 100mL glass tube 38〜46.5 x 113〜120 2,970 with rotor 055-1180
4 x 175/200/225mL conical tube *3,4,8 61 x 118/61 x 130/61 x 137 3,080 055-0780
4 x 250mL *5 60〜62 x 100〜134.4 3,080 055-0780
8 x Self-Standing sputum collection tube cap size φ37 3,020 055-0800
4 x 500mL *9 85 x 135 3,080 ―
Rotor has prescribed operating life cycle and years of operation, after that the rotor must be replaced.
For more details, please contact us.
* The number of times allowed for autoclaving is limited. For more details, please contact us.
*1 The blood collection tube which can be used is Vacutainer 8mL CPT by BD.
*2 5-10mL blood collection tubes which can be used are insepackⅡ and ST series by SEKISUI, VenojectⅡ by TERUMO, Neo tube by NIPRO and Vacutainer by BD.
The tubes for flow cytometry can be used.
*3 175/225mL Falcon conical tubes (catalogue no.352076/352075) require cushions (catalogue no.352090).
*4 200mL Nunc conical tubes (catalogue no.376813) can be used with cushions (catalogue no.377585).
Maximum RCF is 3,020 xg when S-5004 rotor is used.
*5 Nalgene, Herolabo and Corning 250mL flat bottom bottles can be used.
*6 3 types of tubes can be used: 8 x capφ48 (code no.055-0430), 12 x capφ37 (code no.055-0440), 16 x capφ31 (code no.055-0450).
*7 5-7mL thin blood collection tubes which can be used are insepackⅡ and ST series by SEKISUI, VenojectⅡ by TERMO, Neo tube by NIPRO and Vacutainer by BD.
The tubes for flow cytometry can be used.
*8 Sealing caps cannot be used with 200/225mL tubes.
*9 500mL bottles (code no. K15501C/PPCO) can be used.
*10 The bucket cannot be used for a glass spitz tube (tapered tube).
*11 Sealing caps and O-ring (code no.055-0964) are optional.
11