Page 7 - Kubota - 3740
P. 7
3740/3700
The temperature of sample is kept 4℃ at maximum speed of rotation for all rotors (when the ambient temperature is 25℃).
Plate rotor (only for model 3740)
3740
Plate size Adaptor
Rotor Name Nominal Capacity
mm Maximum Speed Maximum RCF Code No.
rpm xg
2 x PCR plate
PF-206 6 x Micro-plate *1 86(W)×128(D)×52(H) 4,000 1,790 ―
2 x Deepwell-plate
PF-206
2 x PCR plates
6 x Micro-plate
2 x Deepwell-plate
These stainless-steel buckets
are chemically resistant.
Swinging bucket rotor (only for model 3740)
Tube
Flow cytometer
tube tube-4
1.5mlTube tube-6-1 tube-6-2 tube-6-3
2mlTube 5ml tube-7-1 tube-7-3 tube-8-1 tube-8-2 tube-8-3 tube-20 tube-7-3 tube-7-1 tube-7-2 tube-8-1 tube-8-2 tube-20
tube-7-2
8 x 7〜10mL blood collection
tube-8-3
5ml 5ml 16 x 5〜10mL blood collection 4 x 7〜10mL blood collection 4 x 7〜10mL blood collection 10ml 15ml
7ml 7ml 7ml 10ml 10ml
7ml
10ml
10ml 15ml
7ml
Nominal Capacity 24 x 1.5/2mL *2 7ml 10ml *3
tube/15mL tube/15mL glass *4 tube/15mL glass *4 tube/15mL glass *4
Tube size (mm) 9.5〜11×36〜42 12〜17×65〜105 12〜17.2×86〜110 12〜17.8×87〜110 12〜17.2×86〜110
diam. x length
Maximum Speed rpm 4,000 4,000 4,000 4,000 4,000
Maximum RCF xg 2,410 2,410 2,540 2,500 2,520
Bucket 053-4800 053-4930 053-4910 053-4990 053-4900
Code No.
BT-67
BT-69
BT-68
BT-65 053-4910 053-4990 053-4900
053-4800
Autoclavable* Adaptor
Code No. 055-7400
SF-240 *5
Max 4,000 rpm — — — —
Max 2,610 xg BT-36
055-7400
BT-37
024-0159 (Rubber cushion)
024-1400
Tube
tube-21
4 x 15mL 4 x 15mL tube-10 4 x 15mL 8 x 15mL 4 x 50mL 4 x 50mL tube-11 4 x 50mL
Nominal Capacity 15ml 50ml 50ml
conical tube×4 conical tube conical tube conical tube glass conical tube conical tube
Tube size (mm)
diam. x length 17×121 17×121 17×121 17×121 27〜37×95〜110 30×117 30×117
Maximum Speed rpm 4,000 4,000 4,000 4,000 4,000 4,000 4,000
Maximum RCF xg 2,580 2,590 2,590 2,580 2,540 2,610 2,610
Bucket 053-4910 053-5010 053-0040 053-4900 053-4990 053-0040 053-5010
Code No.
*5 *5
BT-68 OFX BT-67 BT-69 OFX
053-4910 053-4900 053-4990
Autoclavable* Adaptor 055-1280 055-1280
Code No.
SF-240
Max 4,000 rpm — — — — —
Max 2,610 xg
BT-38 BT-38
055-1280 055-1280
Equipped with sealing cap Equipped with sealing cap
Rotor has prescribed operating life cycle and years of operation, after that the rotor must be replaced.
For more details, please contact us.
* The number of times allowed for autoclaving is limited. For more details, please contact us.
*1 Test the strength of plates before centrifuging. The bottom and lower part of plate might be damaged.
*2 A variety of tube adaptors are available with this rotor. For more details, please contact us.
*3 5-10mL blood collection tubes which can be used are InsepackⅡ by Sekisui, venojectⅡ by Terumo, Neo tube by Nipro and Vacutainer by BD.
The tubes for flow cytometry are available.
*4 7-10mL blood collection tubes which can be used are InsepackⅡ by Sekisui, venojectⅡ by Terumo, Neo tube by Nipro and Vacutainer by BD.
*5 Sealing caps and o-rings are equipped with buckets. These are autoclavable at 121℃.