Page 5 - Kubota - 3740
P. 5
3740/3700
Micro rotor
3740/3700
Tube sizes (mm) Adaptor
Rotor Name Nominal Capacity
diam. x length Maximum Speed Maximum RCF Code No.
rpm *1 xg
18 x 1.5/2mL 9.5〜11.0 x 36〜42 15,000 20,630 ―
AF-2018 18 x 0.5mL 7.0〜7.9 x 25〜34 15,000 18,110 055-7590
18 x 0.2mL PCR *2 5.9〜6.3 x 20〜24 15,000 15,850 055-0500
Autoclavable*
AF-2018
18 x 1.5/2mL
Quick acceleration:
6 seconds (3740)
9 seconds (3700)
3740/3700
Tube sizes (mm) Adaptor
Rotor Name Nominal Capacity Maximum Speed Maximum RCF
diam. x length Code No.
rpm *1 xg
24 x 1.5/2mL 9.5〜11.0 x 36〜42 20,630 ―
12 x 0.5mL *3 7.0〜7.9 x 25〜34 15,000 16,850 ―
AF-2724A 12 x 0.2mL PCR 5.9〜6.3 x 20〜24 14,840 ―
24 x 0.5mL 7.0〜7.9 x 25〜34 15,000 18,360 055-7590
Autoclavable* 24 x 0.2mL PCR *2 5.9〜6.3 x 20〜24 15,000 16,100 055-0500
AF-2724A
24 x 1.5/2mL, 12 x 0.5/0.2mL PCR
4 types of tubes (1.5/2mL,
0.5mL, 0.2mL PCR) can be
used without adaptors.
RCF more than 20,000×g is
effective for BSE tests.
3740/3700
Tube sizes (mm) Adaptor
Rotor Name Nominal Capacity
diam. x length Maximum Speed Maximum RCF Code No.
rpm *1 xg
21,880
36 x 1.5/2mL 9.5〜11.0 x 36〜42 ―
15,000 18,360
12 x 0.2mL PCR *3 5.9〜6.3 x 20〜24 15,340 ―
AF-2236 19,620
Autoclavable* 36 x 0.5mL 7.0〜7.9 x 25〜34 15,000 16,100 055-7590
AF-2236 36 x 0.2mL PCR *2 5.9〜6.3 x 20〜24 15,000 17,360 055-0500
36 x 1.5/2mL, 12 x 0.2mL PCR 13,840
4 types of tubes (1.5/2mL,
0.5mL, 0.2mL PCR) can be
used without adaptors.
Caps of 1.5/2mL tubes can
be placed in the same
direction which is useful for
experiments.
3740
Tube sizes (mm) Adaptor
Rotor Name Nominal Capacity
diam. x length Maximum Speed Maximum RCF Code No.
rpm *1 xg *4
15,780
48 x 1.5/2mL 9.5〜11.0 x 36〜42 12,000 ―
14,010
14,330
AF-2048A 48 x 0.5mL 7.0〜7.9 x 25〜34 12,000 055-7590
12,560
Autoclavable* 12,880
48 x 0.2mL PCR *2 5.9〜6.3 x 20〜24 12,000 055-0500
AF-2048A 11,110
48 x 1.5/2mL
Useful for centrifuging large
number of samples
Rotor has prescribed operating life cycle, after that the rotor must be replaced.
For more details, please contact us.
* The number of times allowed for autoclaving is limited. For more details, please contact us.
*1 The temperature of sample is kept 4℃ at maximum speed of rotation for all rotors (when the ambient temperature is 25℃).
*2 0.2mL PCR tubes may not be used at maximum speed since they may not be resistant enough.
*3 12×0.2mL PCR and 12 × 0.5mL tubes can be used together with outside 24 tube holoes.
*4 Maximum RCF of outside 24 tube hole is the upper value and the maximum RCF of inside 24 tube hole is the lower value in the table.