Page 134 - Shimadu Consumables Catalog
P. 134

TORAST-H Glass Vial



              Features

              Low adsorption vessels treated specially
              Minimized adsorption of bases, acids and neutrals
              Superior quality control




              TORAST -H Glass Technology eliminates the risk of adsorption to the glass surface
             of the vials

           Glass, the material of vials, contains metal oxides. Oxides of
           metals have a high ionizing tendency to be Si-O-M (metal
           silanolate), which may cause ionic adsorption with basic
           compounds in the sample. TORAST-H Glass Technology uses
           special processing to remove metals from the glass and suppress
           adsorption of basic compounds.










              Minimized adsorption of bases, acids & neutrals


           In general, giving a positive charge to the glass surface   Amitriptyline (Basic Compound)  Benzoic Acid (Acidic Compound)
                                                              uV                      2500 uV
           suppresses the adsorption of the basic compounds, but   4500 Control       2250  Control
                                                             4750
                                                             4250
                                                             4000 TORAST-H Glass Vial  TORAST-H Glass Vial
                                                             3750                     2000
           conversely, it causes the adsorption of the acidic compounds.   3500 3250  Recovery: 99.1%  1750  Recovery: 99.5%
                                                             3000                     1500
                                                             2750
           TORAST-H Glass Vials minimize adsorption of both types of   2500 2250      1250
                                                             1750 2000 1500           1000
           compounds.                                        1250 1000                750 500
                                                             750
                                                             500                      250
                                                             250
                                                              0                       0
                                                             -250
                                                              3.2  3.3  3.4  3.5  3.6  3.7  3.8  3.9  4.0  4.1  4.2  4.3  min  1.125 1.150 1.175 1.200 1.225 1.250 1.275 1.300 1.325 1.350 1.375 1.400 1.425 1.450 1.475 1.500  min
                                                                             Benzyl Alcohol (Neutral Compound)
                                                                          uV
                                                                         2000 Control
                                                                         1750 TORAST-H Glass Vial
                                                                                      Recovery: 99.8%
                                                                         1500
                                                                         1250
                                                                         1000
                                                                         750
                                                                         500
                                                                         250
                                                                          0
                                                                           0.900  0.925  0.950  0.975  1.000  1.025  1.050  1.075  1.100  1.125  1.150  1.175  1.200  1.225 min
              Low adsorption for long-term storage
           When a sample is stored in a general vial for a long time, the   Basic Compound A (log P 4.5, pKa 10.5)
           sample may adsorb into the surface of the vial, causing the   100
           reproducibility to be poor. The TORAST-H Glass Vial contains low                  TORAST-H-Glass Vial
           adsorption characteristics that makes it excellent for long term   80
           sample storage.                                          60
                                                                   Recovery (%)  40              Glass Vial A
                                                                    20
                                                                                             Glass Vial B
                                                                                                  Glass Vial C
                                                                     0
                                                                        0hr  24hr  48hr  1week  1month  3month
                                                                           Adsorption test for long-term storage

         Pg B-6
   129   130   131   132   133   134   135   136   137   138   139