Page 8 - LCMS-TQ RX Series
P. 8
Maximize Your Workflow Efficiency
Reliable Resilient Responsible
Intelligent tools to help your workflow efficiency generating higher productivity and better data quality.
LabSolutions Connect MRM Product
Automatically Ensures Instrument Readiness
Preparation
for Analysis
Instrument Check PERFORMANCE CONCIERGE
Automates MRM optimization to create high sensitivity quantitative LC-MS/MS methods.
Mass spectrometer tuning and checks for mass accuracy,
resolution, and intensity can be performed automatically using
LabSolutions Connect MRM not only optimizes target component
the System Check function. The tuning standard is automatically
MRM transitions and collision energies but also maximizes the
injected into the system, and re-tuning can be automatically
response for on column analysis.
initiated if required, resulting in consistent data acquisition and
All optimized acquisition parameters are stored in a data base
laboratory operation without the need of user intervention.
helping to accelerate both method development and routine
Tuning report outputs ensure traceability of instrument status.
analysis.
Optimization of ™
Acquisition Conditions LabSolutions Connect MRM
Supports everything from MRM optimization, creating methods UFswitching: High Speed Polarity Switching (x100,000)
9.0
and batch files for acquisition and processing. 8.5
The RX Series triple quadrupole mass spectrometers have
8.0
unique technology for switching polarity in 5 milliseconds
7.5
between positive and negative ion modes without affecting 7.0
ion intensity. 6.5
6.0
The result is a high data sampling rate across UHPLC peak
5.5
Startup FlowPilot widths of only 2 to 3 seconds even when multiple analytes 5.0
are eluting at the same time. 4.5
Integrated intelligence on the Nexera LC series that allows you to 4.0
™
increase column life-times and reduce consumables by enabling 3.5
3.0
automated column equilibration for flow rates and temperature.
100 100 100 2.5
609.20 >195.20 (+)
138.00 >108.10 (–) 2.0
1.5
% % %
1.0
0.5
0.0
0 0 0
0.0 0.1 0.2 min 0.0 0.1 0.2 min 0.0 0.1 0.2 min 5.50 5.75 6.00 6.25 6.50 min
Measurement UF Data Acquisition
Comparison of measurement using the ultrafast polarity Simultaneous analysis of pesticide residues
Shimadzu's UF technologies opens up new opportunities to do switching (5 msec) and individual measurement spiked into black tea in positive and
of positive and negative ions negative ion modes
more with a single sample, detecting more compounds and
generating even higher data quality.
8 9