Page 10 - LCMS-TQ RX Series
P. 10

Peakintelligence for LCMS                                        Product
                                                           Tools to Help Accelerate Data Processing and
                             Data Analysis
                                                           Report Meaningful Results
                                                                                                                                               Q 216.25>83.10 (+)  Q 255.20>140.90 (+)
                                                                                                                                                           9.03e3            1.25e3
                                                                                                                                                7.5e3            1.0e3
                                                                                                                                                5.0e3
                                                                                                                                                                 5.0e2
                                                                                                                                                2.5e3
                                                                                                                                               0.0e0             0.0e0
                                                                                                                                                  11.5  12.0  12.5   10.5  11.0  11.5
                                                                           ™
                             Peak Integration              Peakintelligence  for LCMS                                                                   Peaks with a low S/N ratio                    1
                                                                                                                                               Q 355.15>88.15 (+)  Q 255.30>91.10 (+)                    3
                                                           Peakintelligence for LCMS is a world-first AI driven peak                             2.0e4      2.07e4  6.0e4     6.21e4
                                                                                                                                                                                                    Data analysis
                                                           integration algorithm requiring zero user settings. The impact is                                     4.0e4                                 time
                                                           dramatic. Peakintelligence for LCMS delivers higher consistency in                   1.0e4            2.0e4                       Conventional  Peakintelligece
                                                           peak integration and results in higher data quality and with far less                                                              Algorithm     for LCMS
                                                                                                                                               0.0e0             0.0e0
                                                           time manually reviewing data.                                                           8.0  8.5  9.0    9.5  10.0  10.5
                                                                                                                                                    Peaks not separated from contaminant
                                                                                                                                                           or isomer peaks
                                                                                                                                                                                        PeakIntelligence for LCMS is an AI driven
                                                                                                                                              PeakIntelligence for LCMS was applied to the   algorithm for component detection and peak
                            Reviewing Data and             LabSolutions Insight ™                                                             analysis of a panel of pesticides in a residue   integration without the need for any user
                             Reporting Results
                                                                                                                                              screening study highlighting consistent peak   parameter. PeakIntelligence for LCMS
                                                           LabSolutions Insight supports a dynamic quantitative data review
                                                                                                                                              integration at low S/N or with overlapping   processing results in higher consistency in peak
                                                           landscape with the tools to drive high confidence in result
                                                                                                                                              components.                               integration and reduces the time-consuming
                                                           reporting by ‘review by exception’. Insight can be configured to
                                                                                                                                                                                        impact of manual review to achieve a more
                                                           check for any outliers outside the scope of user defined criteria for
                                                                                                                                                                                        accurate, more reproducible peak processing.
                                                           reporting results.



                             Maintenance                   Easy Maintenance Shortens Instrument Downtime                                      LabSolutions Insight                                             Product






                      DL Replacement
                                                                                                2
                                                             1

                                                                                                     3
                                       DL (Desolvation Line)


                      ESI Capillary Replacement

                                                                                            3
                                                                  1
                                                                                                                                              LabSolutions Insight is a dynamic data review application, seamlessly integrating quantitative analysis
                                                                                              2                                               and screening capabilities. At its core is the advanced support for ‘review by exception’ applying user
                                                                                                                                              defined reporting criteria to highlight results outside of specified limits. Results that do not meet the
                                          ESI Capillary
                                                                                                                                              rules-based reporting criteria are quickly identified as outliers focusing manual review on the results that
                                                                                                                                              are considered as the exception. The flagged results helps to reduce the impact of reporting false
                                                                                                                                              positive or negative results and streamlines reporting making your laboratory more efficient, more
                     The RX Series keeps the same user-friendly maintenance as its predecessors. Changing the ESI capillary and the
                                                                                                                                              productive.
                     desolvation line (DL), which transports ions into the vacuum region, are designed for quick and effortless replacement
                     without breaking vacuum helping to reduce time spent on maintenance and increase instrument uptime.




        10                                                                                                                                                                                                                                  11
   5   6   7   8   9   10   11   12   13   14   15