Page 10 - LCMS-TQ RX Series
P. 10
Peakintelligence for LCMS Product
Tools to Help Accelerate Data Processing and
Data Analysis
Report Meaningful Results
Q 216.25>83.10 (+) Q 255.20>140.90 (+)
9.03e3 1.25e3
7.5e3 1.0e3
5.0e3
5.0e2
2.5e3
0.0e0 0.0e0
11.5 12.0 12.5 10.5 11.0 11.5
™
Peak Integration Peakintelligence for LCMS Peaks with a low S/N ratio 1
Q 355.15>88.15 (+) Q 255.30>91.10 (+) 3
Peakintelligence for LCMS is a world-first AI driven peak 2.0e4 2.07e4 6.0e4 6.21e4
Data analysis
integration algorithm requiring zero user settings. The impact is 4.0e4 time
dramatic. Peakintelligence for LCMS delivers higher consistency in 1.0e4 2.0e4 Conventional Peakintelligece
peak integration and results in higher data quality and with far less Algorithm for LCMS
0.0e0 0.0e0
time manually reviewing data. 8.0 8.5 9.0 9.5 10.0 10.5
Peaks not separated from contaminant
or isomer peaks
PeakIntelligence for LCMS is an AI driven
PeakIntelligence for LCMS was applied to the algorithm for component detection and peak
Reviewing Data and LabSolutions Insight ™ analysis of a panel of pesticides in a residue integration without the need for any user
Reporting Results
screening study highlighting consistent peak parameter. PeakIntelligence for LCMS
LabSolutions Insight supports a dynamic quantitative data review
integration at low S/N or with overlapping processing results in higher consistency in peak
landscape with the tools to drive high confidence in result
components. integration and reduces the time-consuming
reporting by ‘review by exception’. Insight can be configured to
impact of manual review to achieve a more
check for any outliers outside the scope of user defined criteria for
accurate, more reproducible peak processing.
reporting results.
Maintenance Easy Maintenance Shortens Instrument Downtime LabSolutions Insight Product
DL Replacement
2
1
3
DL (Desolvation Line)
ESI Capillary Replacement
3
1
LabSolutions Insight is a dynamic data review application, seamlessly integrating quantitative analysis
2 and screening capabilities. At its core is the advanced support for ‘review by exception’ applying user
defined reporting criteria to highlight results outside of specified limits. Results that do not meet the
ESI Capillary
rules-based reporting criteria are quickly identified as outliers focusing manual review on the results that
are considered as the exception. The flagged results helps to reduce the impact of reporting false
positive or negative results and streamlines reporting making your laboratory more efficient, more
The RX Series keeps the same user-friendly maintenance as its predecessors. Changing the ESI capillary and the
productive.
desolvation line (DL), which transports ions into the vacuum region, are designed for quick and effortless replacement
without breaking vacuum helping to reduce time spent on maintenance and increase instrument uptime.
10 11