Page 18 - Shimadzu-FoodSafety
P. 18

Halal Testing                                                                                                             Laboratory Data Management






                    The unauthorized blending of undeclared materials into food products has become a major concern among consumers.          The increased demand for food safety analysis and measurement has led to a dramatic increase in the number of samples
                    Such action violates customer rights based upon economical and safety values and it is also a critical problem for communities   being analyzed which, in turn, has resulted in demands for faster, easier-to-use instruments and software. With this
                    with ethical and religious beliefs. Shown below are the results from an analysis using a high-sensitivity LC-MS/MS method for   background, faster, more efficient management of instruments and data is essential. LabSolutions is a network-compatible
                    ensuring halal food integrity by targeting more heat-stable porcine-specific peptide markers in processed food.           analysis data system capable of meeting these needs.



                                                                                                                                                                       LabSolutions CS – Total Laboratory Network

                      Peptide    Spiking Percentage of Cooked Pork (%, wt) [n=4]
                      Marker                                                                                                                  Freely Accessible to the Analysis Network          Recommended for the following customers
                                 0.1      0.5      1.0       5.0
                       YDII       +       +         +        +                                                                                Since all analytical data is managed in the database of a   ・Facilities with a large number of instruments and users
                       LVVI       +       +         +        +                                                                                server computer, LabSolutions CS can read data from any   ・Facilities interested in enhancing procedural efficiency
                                                                                                                                              personal computer on a network. In addition, analysis   ・Facilities interested in enhancing managerial efficiency
                       EVTE      ND       ND       ND        +
                                                                                                                                              directions and instrument monitoring and control can be   ・Facilities where existing PCs can be used as client PCs
                       TVLG      ND       ND       ND        ND
                                                                                                                                              performed from a personal computer (client PC) not
                       FVIE      ND       +         +        +                                                                                connected to the instruments.
                       TLAF      ND       ND        +        +                                                                                Moreover, client PC functions are performed on a server and
                       SALA       +       +         +        +                                                                                client PCs corresponding to a Windows terminal service do
                                                                                                                                              not need to install LabSolutions software.




                     Peptide                                                                                                                                                                              LabSolutions server
                    Candidate  FASTA format
                    Selection  download via  MRM Prediction  Method Development                                                                                   Client PC          Analysis equipment
                             UniProt Database  via Skyline  & Analysis                                                                                                               room or an office


                      (x1,000)        (x1,000)        (x1,000)           Area(x10,000)            Area(x100,000)
                       453.80>628.40(+)  450.30>687.40(+)  376.10>392.80(+)
                                       MRM1
                    1.00 453.80>279.10(+)  450.30>588.35(+)  Pork  376.10>647.20(+)
                                                       MRM1
                       MRM1
                                                       MRM2
                                       MRM2
                       MRM2
                       453.80>515.35(+) YDII Pork  450.30>475.25(+)  LVVI  1.5 376.10>576.40(+)  SALA Pork  7.5  1.5
                       MRM3   0.1%     MRM3    0.1%    MRM3    0.1%         (A)                     (B)
                    0.75  YDII       1.5  LVVI
                                                     1.0  SALA          5.0                     1.0
                    0.50             1.0
                                                                        2.5                     0.5
                                                     0.5
                    0.25             0.5
                                                                        0.0                     0.0
                    0.00             0.0             0.0                                                                                                 Acquisition
                      6.0  6.5  7.0     5.0  5.5  6.0     3.0  3.5       0.0      2.5     Conc.  0.0      2.5     Conc.                                 controller PC       UV            FTIR          RF          ICPMS
                      (x1,000)        (x10,000)       (x1,000)           Area(x10,000)            Area(x10,000)
                      453.80>628.40(+)  450.30>687.40(+)  376.10>392.80(+)                      7.5
                       MRM1
                      453.80>279.10(+)  Pork  450.30>588.35(+)  376.10>647.20(+)
                                       MRM1
                                                       MRM1
                       MRM2
                                       MRM2
                                                       MRM2
                     4.0  453.80>515.35(+)  YDII  1.0%  1.25 450.30>475.25(+)  LVVI Pork  3.0 376.10>576.40(+) SALA Pork  1.5  (C)  (D)
                                       MRM3
                       MRM3
                                              1.0%
                                                       MRM3
                                                               1.0%
                        YDII        1.00  LVVI
                     3.0                                                                        5.0
                                    0.75             2.0      SALA      1.0                                                                                                                                   GCMS     AA    TOC
                     2.0
                                    0.50                                                        2.5
                                                     1.0                0.5
                     1.0
                                    0.25
                                                                                                                                                                                                                EDX      Particle size
                     0.0            0.00             0.0                0.0                     0.0                                                                                                                       analyzer
                        6.0    7.0     5.0   5.5  6.0     3.0    4.0     0.0      2.5     Conc.  0.0      2.5     Conc.                                                                                   Combine with a Multi Data Registration license to enable
                                                                                                                                                            LC   GC    LC    GC                           integrated management of these instruments’ data.
                                                                                            Source: Shimadzu Application News No. AD-0153
                    In summary, the established MRM-based method on a LC-MS/MS platform offers a highly sensitive and selective approach to
                    detect and monitor the presence of porcine-specific markers for semi-quantitation of the amount of pork in processed foods.
                    The established method from sample preparation to LC-MS/MS analysis exhibits excellent reliable sensitivity, and is potentially
                    able to support halal testing in processed food products. Analysis of various food matrices will be performed in the future.
                                                                                                                                                                                          Shimadzu’s Total Support for Food Safety
             18                                                                                                                                                                                                             Analytical and Testing Instruments for Food Safety  19