Page 8 - Shimadzu XSeeker 8000
P. 8
Operation Optimized for Inspections Supporting the Safety and Security of Users
Scanning in as Little as 12 Seconds and Status Monitor
High-Speed Reconstruction Calculations In addition to displaying the instrument status, including the stage position during normal operation, the
monitor provides details of any errors that occur during abnormal operation and the site where the
High-speed scanning can take as little as 12 seconds. In addition, the system is equipped with the same problem occurs, so the operator is notified of the problem immediately.
reconstruction system as high-end models, so CT data can be displayed a mere 10 seconds after scanning is The status of the system as a whole is always monitored, from warnings that the sliding door is not shut,
complete. This is approximately twice as fast as Shimadzu’s other CT models. for example, to alarms indicating overheating of the X-ray generator and communications faults.
As little as 12 sec
Data acquisition 10 sec Data display
XSeeker 8000 Approx. twice as fast
Reconstruction calculations Saving
Data acquisition 10 sec Data display
Shimadzu’s Other
CT Models
Reconstruction calculations Saving
Newly Developed Control Software
Enables Intuitive Operations During Normal Operation During Abnormal Operation
The simple user interface which eliminates complicated steps, enables intuitive operation so that anyone
can easily use the system.
There are dedicated windows for scanning and observation, respectively, and the user is free to switch Safety Compliant with CE Marking
between them.
Door damper for
1µSv/h or less external X-ray leakage preventing jammed fingers
Equipped with a safety box to The damping mechanism
ensure that the above-mentioned ensures that the sliding door
leakage is not exceeded even with moves slowly and quietly
90 inspections per hour. when samples are inserted or
removed, so jammed fingers
are prevented.
Electromagnetic lock
Scan Window Observation Window
The system is equipped with
an electromagnetic lock
mechanism, so the sliding door
Recommend cannot be opened during
irradiation.
Scanning Function Select from two materials
The system is equipped with an recommend CE-compliant design
scanning function, which can set all the scanning Safe rotating table control
conditions with a single click. The optimal scanning Select from The interlock, indicators, and other
two image qualities The power is shut down while
conditions can be set easily just by selecting one safety features are designed for the sliding door is open so
compliance with CE marking.
combination of material and image quality. that the rotating table cannot
move.