Page 6 - Shimadzu XSeeker 8000
P. 6

Operation Optimized for Inspections







                       3-Step Scanning                                                                                                     Operation at the Push of a Button

                     A simple 3-step process enables starting observations. Upon installation, new operators can run the system         In inspection applications with repeated scanning of samples with the same shape, operation at the push
                     with minimal training.                                                                                             of a button enhances throughput.
                     Calibration is not required prior to sample placement.                                                             The optimal conditions, including the position displayed and the contrast during observations, are record-
                                                                                                                                        ed together with the scanning conditions. This allows observations to begin immediately after scanning
                                                                                                                                        without adjusting the observation position or contrast. All operations from starting the scanning to
                                                                                                                                        observing the results can be completed at the push of a button, without any software operations.

                                 Positioning the Sample
                                                                                        Max.
                        ST E P                                            φ300 mm     CT-Scan Region
                       01        The system is equipped with a unique                                                                      Suitable for lot inspections!
                                 sample placement support mechanism.  320 mm  φ100 mm
                                 It visualizes the CT-Scan region with    80 mm
                                 guide lights to enable easier sample                   Max.
                                                                                       sample size
                                 placement.









                                 Setting the Scanning Conditions
                        ST E P
                       02        The conditions can be selected with a single click

                                 from four simple conditions buttons. (Recommend
                                                                                                                                           ST E P     Setting the scanning conditions is unnecessary!
                                 Scanning Function: Page 8)
                                                                                                                                           01
                                                                                                                                                    Positioning the Sample

                                                                                                                                                    Samples with the same shape are positioned at a set position on the stage.
                                                                                                                                                    A function reproduces the scanning conditions, making it unnecessary to set the conditions
                                 Scanning                                                                                                           again for each sample.
                        ST E P
                       03        Click the Scan start button to start scanning.
                                 Scanning takes as little as 12 seconds.
                                                                                                                                                                                                      One button!


                                                                                                                                           ST E P         Setting observation
                                                                                                                                           02           conditions automatically!

                       Observation
                                                                                                                                                    Scanning and Observation
                       In the observation window, the displayed position,
                       brightness, and contrast of the cross-sectional and                                                                          After positioning the sample, press
                       VR images are adjusted to ensure the optimal                                                                                 the CT start button on the main unit
                       display of the region to observe.                                                                                            to start scanning. The observation
                                                                                                                                                    conditions are automatically set, so
                                                                                                                                                    with just a push of a button, the
                                                                                                                                                    region to observe is displayed with
                                                                                                                                                    the optimal conditions.




        6                                                                                                                                                                                                                                    7
   1   2   3   4   5   6   7   8   9   10   11