Page 10 - Shimadzu Xctal 5000
P. 10

Anyone Can Easily Perform New Observations







                     Three-Step Scan                                                                                                    Optional Software



                                                           Scanning
                       Placement of the Sample                                          Scanning
                                                           condition setting                                                            HADI-S
                                                                                                                                        2D Image Processing Software

                                                                                                                                        This can perform a variety of image processing on
                     Place the applicable sample on the stage.  Configure the grating and   Calibration before scanning is               2D projection images and cross-sectional images,
                                                          image quality settings. The   not required, so CT scanning                    including size measurements and filter processing.
                      Available sample size               settings are configured just   can start immediately. After
                          Φ150 mm
                                                          with pull-down menus and    scanning is finished, software
                                          Maximum         checkboxes, enabling scanning   (Viewer or MPR) for
                                        scanning range    to start easily.            observations and analysis                                                                                      (Smart Vision Corporation)
                                          Φ100 mm
                                                                                      corresponding to the scanning
                                                                                      method starts up automatically.
                                    H275 mm
                                                   H100 mm

                                                                                                                                        VGSTUDIO MAX
                                                                                                                                        3D Image Processing Software
                     Standard Software                                                                                                  This is high functional volume rendering (VR)

                                                                                                                                        software. Multiple functions are available including
                                                                                                                                        the creation of animations, various measurements,
                                                                                                                                        extirpation of the center region, image filtering, and
                                                                                                                                        positional alignment of 3D images.
                     Xctal
                     Control Software                                                                                                                                                                  (Volume Graphics)

                     Functions include system control, fluoroscopy, CT scan,
                     and reconstruction.                                                                                                Main Specifications


                                                                                                                                                         Model                                     Xctal 5000
                                                                                                                                          X-Ray Generator Output               Max. tube voltage 90 kV    Max. tube current 800  A    Rated Output 50 W
                     XctalViewer                                                                                                          X-Ray Detector                                         Flat panel detector
                     Viewer Software                                                                                                      Available     CT Stage                            Φ150 mm × H275 mm    Max. 5 kg
                                                                                                                                          Sample Size
                                                                                                                                                        Orientation Analysis Unit           Φ100 mm × H10 mm    Max. 300 g
                     This software displays the X-ray 2D projection images                                                                              Fluoroscopy                              100 mm × 100 mm
                     and cross-sectional images from scans with Xctal 5000.
                     In addition to displaying images, it can output vector                                                                             Fiber Orientation                           Φ100 mm
                     direction color maps created from multiple dark-field                                                                 Max. Scanning   Fluoroscopy
                                                                                                                                          Range
                     images.
                                                                                                                                                        CT Scan                                 Φ100 mm × H100 mm
                                                                                                                                                        Fiber Orientation CT Scan                Φ85 mm × H85 mm
                                                                                                                                          CT Data Acquisition Time                                Min. 30 minutes
                                                                                                                                                        Main Unit                    Single phase 200 to 230 VAC ± 10 %    50/60 Hz, 1.0 kVA
                                                                                                                                          Rated Power   Control Computer             Single phase 100 to 230 VAC ± 10 %    50/60 Hz, 1.5 kVA
                     MPR(Xctal)
                                                                                                                                                        Grounding                           Grounding resistance of 100   max.
                     This software displays cross-sectional images obtained                                                               Weight                                                     1700 kg
                     with the Xctal 5000. Four cross-sectional images at any
                     angle can be displayed simultaneously.                                                                                                                                 Ambient temperature 20 to 30 °C
                                                                                                                                          Operating Conditions (when running)
                                                                                                                                                                                      Ambient humidity 40 to 80 % max. (no condensation)
                                                                                                                                          External Leakage Dose                                    1  Sv/h or less



        10                                                                                                                                                                                                                                  11
   5   6   7   8   9   10   11   12