Page 6 - Shimadzu TOC-4200
P. 6

Diverse Applications



                     Measurement speed is the key feature of combustion catalytic oxidation TOC analyzers.
                     This characteristic can be exploited to support a diverse range of applications.





                     ˙ Wastewater treatment plant influent (upstream monitoring) and effluent                                             Example of Installation for Upstream Monitoring

                     • Measurements at a short measuring cycle (4 minutes minimum) rapidly capture
                      dramatic changes in organic matter or abnormal effluent.
                                                                                                                                                                                                                          River
                     • The powerful oxidation capacity of a combustion-type analyzer can detect organic                                   Plant A
                                                                                                                                                                                TOC (2)                   TOC (1)
                      matter that cannot be captured using a UV meter.
                     • The short measuring cycle and powerful oxidation, combined with switching between
                      up to six flow lines, offer detailed monitoring of treatment plants.                                                Plant B


                     ˙ Monitoring of river water sampled at water purification plants and                                                  Plant C                                          Treatment                      Effluent
                                                                                                                                                                                TOC (3)     plant
                       treated water (tap water)
                     • Monitoring changes in river water quality due to rainfall and other factors to provide
                      control indicators for the treatment processes                                                                                       Cooling water
                     • Permits simultaneous monitoring of treated tap water.
                                                                                                                                                             Rainwater

                     ˙ Supports monitoring TOC removal rate based on EPA Regulations.                                                   TOC (1)  Prevents water pollution accidents through rapid detection of abnormal effluent.
                                                                                                                                        TOC (2)  Identifies the source of abnormal effluent to accelerate identification of the cause and prevention of recurrence (three-flow-line switching).
                     • Calculates TOC removal rate based on the U.S.A EPA regulations (Part IV 40 CFR Part 9,                           TOC (3)  Monitoring of effluent not from the treatment plant
                      141 and 142, 1998). (*1)
                                                                                                                                                                                                                          Public
                                                                                                                                            Process A                    TOC (1)  TOC/TN (2)      TOC/TN (3)            water body
                                                                                                                                                                                                                        (river, ocean)
                     ˙ Total pollutant load control regulation applications (organic pollution load)

                     • Converting the measured TOC values allows applications to COD total volume control. (*2)                             Process B
                      TOC → COD conversion functions are installed as standard.
                     • Reading flow rate signals from a flow meter (*1) permits COD load conversion calculations.
                                                                                                                                            Process C                              Water                   Flow           Effluent
                                                                                                                                                                                  treatment                meter
                                                                                                                                                                                   plant
                     ˙ Plant water                                                                                                                                                                 TOC (5)
                       (washing water, cooling water, recovered water, boiler water, condensate,
                                                                                                                                               Cooling water                   TOC (4)
                       etc.)
                                                                                                                                                Rainwater                                                    Water
                     • Continuous monitoring of water used in a plant
                                                                                                                                                                                                          purification plant
                     • Continuous monitoring of pure boiler water assists in the detection of anomalies, such
                                                                                                                                                                                                                Tap water
                      as damaged pipes.
                     • The short measuring cycle (4 minutes minimum) of the combustion-type TOC analyzer                                TOC (1)  Monitoring of TOC values discharged from each process (three-flow-line switching)
                                                                                                                                        TOC (2)  Monitoring of inflow and outflow of water treatment plant (two-flow-line switching). Optimization control of treatment performance
                      achieves more rapid detection of anomalies.                                                                             (amount of aeration, etc.) at the water treatment plant
                                                                                                                                        TOC (3)  Monitoring of all effluent discharged from the enterprise. Load conversion calculations using flow rate signals input from a flow meter
                                                                                                                                        TOC (4)  Monitoring of abnormal values for cooling water and rainwater. Monitoring for abnormalities in the pipe system (two-flow-line switching)
                                                                                                                                        TOC (5)  Monitoring of water taken in the water purification plant. Monitoring for abnormalities in the tap water
                     *1 Optional
                     *2 The TOC-COD conversion formula must be determined separately.