Page 2 - Shimadzu ON-LINE TOC-VCSH
P. 2

This on-line TOC analyzer offers both high sensitivity

            and superior oxidation performance for organic materials.






               On-line Models                                                                                                            Combustion catalytic oxidation/NDIR method


            ON-LINE TOC-VCSH                                                                                                          Measurement flow line diagram
            A function for continuous automatic                high-sensitivity measurement of organic
            measurement has been added to the ability of       substances. The On-line TOC-VCSH can be used for                         ON-LINE TOC-VCSH           Acid
            the combustion catalytic oxidation/NDIR TOC-V      continuous automatic high-sensitivity monitoring                         Sample            Autosampler               Dilution water
            Series to perform high-performance,                of samples such as pure water and tap water.                               line               OCT-I
                                                                                                                                                                                Multi-function      Non-dispersive
                                                                                                                                                                                sample pretreatment/  infrared detector
                                                                                                                                                                                injection system        (NDIR)
                                                                                                                                                                             Drain                                  Data      Analog output
                                                                                                                                                           Sparge  TC injection port,                             processor  4-20 mA/0-16 mA
                                                                                                                                                              gas                                                                /0-1 V
                                                                                                                                                    Gas flow            slide type  Blank check   IC injection port,
                                                                                                                                                      rate                     ultrapure water  slide type
                                                               Extremely wide range from 4 µg/L to 25,000 mg/L for                         Carrier gas   controller Carrier gas  trap
                                                               applications from ultrapure water to highly contaminated                       inlet
                                                               water.                                                                                 TC combustion tube
                                                                                                                                                                                              IC reagent
                                                                 Combination of highly sensitive NDIR with a high-volume sample combustion                                                           Dehumidifier/
                                                                 system achieves sub-10 µg/L level TOC analysis.                                                                                  gas pretreatment unit
                                                                 Specify the blank check program to automatically conduct the blank check                 TC furnace                         IC reaction vessel
                                                                 by creating and analyzing ultrapure water inside the system.
                                                                 High concentration samples are analyzed by diluting to 25,000 mg/L the
                                                                 built-in automatic dilution function.

            Combines Combustion Catalytic Oxidation at 680°C and NDIR   Support Software for Pharmaceutical Water Management          TC (Total Carbon) Measurement                      IC (Inorganic Carbon) Measurement
            Method                                             Applications
                                                                                                                                      Carrier gas (purified air) is passed at a controlled flow rate   The acidified sample is sparged with the carrier gas (purified
            Combustion catalytic oxidation at 680°C oxidizes even persistent or insoluble   The On-line TOC-VCSH incorporates software for automatically performing tests   of 150 mL/min through an oxidation catalyst-filled TC   air) to convert only the IC in the sample to carbon dioxide.
            organic compounds. This method accurately measures any type of organic   specified by Japanese Pharmacopeia (resolution test) and USP (system suitability   combustion tube, heated to 680°C. When the sample   This carbon dioxide is detected by the NDIR and the sample
            substance not affected by interfering substances or the sample properties such   test). Combining the On-line TOC-VCSH with an OCT-1 (optional) enables fully
            as pH or conductivity.                             automatic testing; setting the reagent is the only requirement.        pretreatment/injection system injects the sample into the   IC concentration is measured in the same way as TC.
                                                                                                                                      combustion tube, the TC in the sample is oxidized or   The IC is a combination of carbonate and bicarbonate.
                                                                                                                                      decomposes to create carbon dioxide. The carrier gas
            Easy Maintenance
                                                                                                                                      carrying the combustion products from the combustion tube   TOC (TC-IC) Measurement
            Combustion catalytic oxidation at 680°C eliminates the need for oxidizing                                                 is cooled and dehumidified in the dehumidifier before
            reagents, saving the tasks of procuring and preparing reagents. No special                                                passing via the halogen scrubber into the sample cell of the   Subtracting the IC concentration from the TC concentration
            draining operations are needed.                                                                                           non-dispersive infrared detector (NDIR), where the carbon   determines the TOC concentration.
                                                                                                                                      dioxide is detected. The NDIR analog signal forms a peak,
            Off-line Measurement Functions                                                                                            and the data processor calculates the peak area.   NPOC Measurement (TOC by acidification/ sparging method)
                                                                                                                                      To measure the TC concentration of the sample, the
            A dedicated on-line measuring port is provided for easily conducting                                                                                                         A small amount of hydrochloric acid is added to acidify the
            interrupting analyses. The optional OCT-1 allows the automatic measurement of                                             relationship between the TC concentration and peak area   sample, which is then sparged with sparge gas. This converts
            up to 15 samples.                                                                                                         (calibration curve) is predetermined using a TC standard   all IC in the sample to carbon dioxide and drives the CO2 out
                                                                                                                                      solution, to express the peak area as a ratio of the TC   of the sample solution. The TOC concentration is determined
            Wide Variety of TOC Measurement Methods                                                                                   concentration.                                     by measuring the TC of the sample after the IC is eliminated.
                                                                                                                                      TC comprises TOC (Total Organic Carbon) and IC (Inorganic
            NPOC, IC, TC and TOC (TC-IC) measurements are possible with the On-line                                                   Carbon).                                           NPOC measurement is equivalent to TOC measurement using
            TOC-VCSH. TN measurement is also possible by adding an optional product. TOC                                                                                                 acidification and sparging (IC elimination) defined for
            and TN can be measured simultaneously.                                                                                                                                       official test methods (EPA, ASTM, EN, etc.). As any purgeable
                                                                                                                                                                                         organic compounds may be lost from the sample during
                                                                                                                                                                                         sparging, the TOC measured by this method can be called
            Main Applications                                                                                                                                                            NPOC (Non-Purgeable Organic Carbon).
            Management of pharmaceutical water
            Management of ultrapure and recycled water for the semiconductor industry
            Management of mains water
            Impurity contamination management for all types of water used at plants (cooling water, recycled water, and boiler water)
   1   2   3   4