Page 16 - Shimadzu Nexis GC-2030
P. 16
Petrochemical Monitoring Sulfur in Diesel Oil Distillates
Using a detector splitting device with minimal dead volume, it is possible to analyze the components in diesel oil comprehensively
Refinery Gas Analysis System 2 3 [FID] with MS, while simultaneously measuring* the sulfur components selectively and with high sensitivity using an SCD.
+
1. C 6
6 2. Methane
Specialized systems can be con gured by installing multiple 8 13 3. Ethane
valves and columns in the standard Nexis GC-2030 installation 4 5 17 18 4. Ethylene MS(TIC)
5. Propane
space. Inorganic gases, hydrocarbons, hydrogen sul des, and 7 11 12 14 21 22 6. Propylene
7. Isobutane
other components can be analyzed within ve and a half 1 9 10 15 16 19 20 8. n-Butane
minutes. Method development is not required because systems 9. Propadien
10. Acetylene
are assembled and tested in advance at the factory, prior to 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 min 11. trans-2-Butene
12. 1-Butene
arriving at your lab. Re nery Gas Analysis (FID) 13. i-Butene
14. cis-2-Butene
15. Isopentane
29 30 16. n-Pentane
17. 1,3-Butadien
18. Methylacetylene
19. trans-2-Pentene
28 20. 2-Methyl-2-butene
21. 1-Pentene
23 26 27 22. cis-2-Pentene SCD
25
24 31 [TCD-1]
23. Carbon dioxide
™
24. Ethylene GCMS-QP2020 NX + SCD-2030 + AOC -30i
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 min 25. Ethane Di-tert-butyl disulfide
26. Acetylene
Re nery Gas Analysis (TCD-1) 27. Hydrogen sul de
28. Oxgen * LabSolutions DB GCMS or LabSolutions CS is required to acquire data
29. Nitrogen
30. Methane simultaneously from a GCMS and SCD.
31. Carbon Monoxide
32 [TCD-2]
32. Hydrogen Simultaneous Analysis of Sulfur Standard
Components in Diesel Using GC-MS and SCD
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 min
Re nery Gas Analysis (TCD-2)
Environment Xylenes
Acetonitrile Toluene
Analysis of VOCs in Ethylbenzene
Analysis of Simulated Distillation Work Environments
Simulated Distillation GC Analysis Software integrated with Trace components in the air can be
LabSolutions is compliant with ASTM, ISO, and various other concentrated for measurement via thermal Hexane Standard
sample
standards that specify distillation GC. With high boiling point desorption. The TD-30 can accommodate 100 ng
compounds, sample loss can be minimized by using the up to 120 samples, and thanks to the Room air
OCI-2030 NX injection port.
repeated collection function, if a precious 2.0 3.0 4.0 5.0 6.0 min
sample is analyzed incorrectly, it can be Analysis of VOCs in Work Environments Nexis GC-2030 + TD-30
™
measured again.
Compatibility with Simulated
Distillation GC Analysis Software Simulated Distillation GC Analysis Software
Coordinating with
Carbon number Sample
ASTM D 3710,D 7096 n-C3 to n-C15 Gasoline, naphtha Compatible Products
JIS K 2254 - Kerosene, diesel
ASTM D 2887 (ISO3924, IP406) n-C5 to n-C44 Jet fuel, diesel
By coordinating with other brands of
ASTM D 6417 n-C8 to n-C60 Lubricant oil, base oil
pretreatment systems, detectors, and
ASTM D 7213(Extended D2887) n-C7 to n-C60 Lubricant oil, base oil
analysis software, an application system
ASTM D 6352 n-C10 to n-C90 Lubricant oil, base oil
can be constructed that is compatible
ASTM D 7500 n-C7 to n-C100 Lubricant oil, base oil with various standards, methods, and
EN 15199-1 (IP480, DIN 51435) n-C7 to n-C120 Lubricant oil, base oil regulations.
ASTM D 5307 to n-C44 Crude oil (internal standard method) Examples: MOSH/MOAH analysis; PIONA
analysis; analysis of VOCs in water;
Crude oil (external standard method,
ASTM D 7169, EN 15199-2 (IP 507) n-C7 to n-C100 up to n-C120 for EN)
Chromatogram of Polywax (ASTM D 7500) analysis of gases produced by high
polymer materials; and analysis of AOC -6000 Plus EGA/PY-3030D Pyrolizer
™
* Please contact Shimadzu representatives for
more details of compatibility phthalate esters in flame retardants. Multifunctional Autosampler (Frontier Laboratories)
16 Gas Chromatograph 17