Best-in-class* Sensitivity and Reproducibility








                     Achieves Exceptional Reproducibility                                                                               High-Sensitivity Detectors
                                                                                                                                        Support a Wide Variety of Analyses

                     Nexis GC-2030 provides best-in-class analysis accuracy. Shimadzu's new AOC-30
                     auto injector automates the analysis, reduces an operator's workload, and
                     enables continuous analysis with a high degree of accuracy that cannot be                                          Barrier Discharge Ionization Detector (BID)                       Quartz tube  He plasma
                     achieved by manual operation. In addition, an advanced  ow controller (AFC)                                                                                                       (dielectric substance)  He
                     included in the CPU supports carrier gas constant linear velocity control, constant                                The barrier discharge ionization detector (BID-2030) is a universal detector that
                      owrate control, constant pressure control, and various other control modes and                                    offers high-sensitivity analysis by using a low-frequency dielectric barrier discharge   Column
                     achieve s exce p tionally high re p ro du cibilit y for ultra - high - s p e e d an d                              plasma for ionization. The BID generates a helium (He) plasma by applying a high
                     ultra-high-precision control modes.
                                                                                                                                        voltage to a quartz glass tube. The light energy from the He plasma then ionizes the
                                                                                                                                        target components and the ions are collected and output as peaks using a collection
                                                                                                                                        electrode. A wide variety of compounds other than He and neon (Ne) are detected
                                                           9
                           1     4                     8                                                                                with high sensitivity.
                                                                        1  n-Decane  0.162  6  Methyl nonanoate  0.157                                                                                  Barrier Discharge Ionization Detector
                                3              7                                                                                                                                                                 (BID-2030)
                              2     5
                                         6                              2  n-Octyl alcohol  0.163  7  Methyl decanoate  0.141
                                                                        3  2,6-Dimethylphenol  0.160  8  Methyl dodecanoate 0.180
                                                                                                                                                                                                            Collector
                                                                        4  n-Undecane  0.145  9  Dicyclohexylamine  0.208               Flame Ionization Detector (FID)
                                                                                                                                                                                                                        Nozzle
                                                                        5  2,6-Dimethylaniline  0.149
                                                                                                                                        The jet and collector structure on the  ame ionization detector (FID-2030) has been
                                                                                                                                        optimized to provide improved performance. Noise levels were also decreased by
                        2.5  3.0  3.5  4.0  4.5  5.0  5.5  6.0  6.5  7.0  7.5  8.0  8.5  min
                                                                                                                                        improving the stability of the signal processor and  ow controller. This results in the
                                 Chromatogram Overdraw (n=10)                   Area Reproducibility (%RSD)                             world’s most sensitive FID*.
                                                                                                                                                                                                            Flame Ionization Detector
                                                                                                                                                                                                                 (FID-2030)
                     AOC -30 Series Autoinjectors
                          ™
                                                                                                                                        Sulfur Chemiluminescence Detector (SCD)
                                                                                                                                                                                                       Ultra Short
                     The AOC-30 can automate analyses with up to 150 samples. This not only eases                                       SCDs are the most sensitive GC detectors for measuring sulfur components. The   Flow Path
                     the burden on operators, but also enables high-accuracy consecutive analyses                                       Nexis SCD-2030 is equipped with an ultra short  ow path and high ef ciency redox
                     that cannot be achieved manually. Pretreatment just before sample measurement                                      cell, so it provides the world’s highest level* of sensitivity and stability.
                     and injection is overlapped, improving throughput during consecutive analyses.                                     In addition, detector startup is automated, easing the burden on operators.
                     Shimadzu’s proprietary injection method limits damage to the septum and
                     contamination of the injection port insert, thereby achieving high reproducibility.
                                                                                                                                                                                                                     The Redox Cell

                                                                                                                                                                                                        Sulfur Chemiluminescence Detector
                                                                                                                                                                                                                 (SCD-2030)
                     Inlets
                                                                                                                                        Other Detectors
                     Split/Splitless Injector (SPL)

                     -  The carrier gas saver function reduces split gas consumption.                                                   Thermal Conductivity Detector (TCD)           Electron Capture Detector (ECD)
                     -  Inactivation options
                                                                                                                                        -  Enables more reliable analysis that is less easily affected by   - High sensitivity and a wide dynamic range are achieved by
                                                                                                                                         column oven temperature.                      adopting ECD cell structure and purge  owrate optimization,
                                                                                                                                        -  Analysis for inorganic gases and high-concentration organic   as well as highly durable materials.
                     Direct Injection Unit (WBI)                   Programmed Temperature Vaporization Injector (PTV)                    compounds.                                   - Analysis for electrophilic compounds.
                     -  Shares and simpli es the glass inserts for splitless analysis   -  Uses an inert heat-resistant quartz insert.
                      (patented).
                                                                                                                                        Flame Photometric Detector (FPD)              Flame Thermionic Detector (FTD)
                                                                                                                                        - A novel optical system with a more advanced dual-focus   - An improved collector reduces the negative peaks from
                     On-Column Injection Unit (OCI)                Packed Column Injection Unit (SINJ)                                   system results in the world's highest* sensitivity.  impurity components.
                                                                                                                                        - Analysis for organic phosphorus compounds and sulfur   - Collectors can be replaced without tools.
                     -  Supports analysis of high-boiling compounds (straight-chain   -  Glass packed column and SUS packed column can be   - compounds.                              - Analysis for organic nitrogen compounds and organic
                      hydrocarbons with 100 or more carbons)        connected.                                                                                                         phosphorus compounds.

                                                                               * As of July 2021, according to a Shimadzu survey                                                                   * As of July 2021, according to a Shimadzu survey