Page 8 - Shimadzu Nexis GC-2030
P. 8

Designed with the Analyst in Mind








                                  STEP 03                                                                                               Making Routine Analysis
                                 Post-analysis                                                                                          More Convenient                                                            Maintenance
                                                                                                                                                                                                                    Instruction
                                                                                                                                        2D Code Navigation

                     Process Large Volumes of Data with High Precision in a Single Step                                                 Reading a 2D code shown on the touch panel directs the
                                                                                                                                        user to a website with instructional videos on maintenance.
                     – i-PeakFinder  Automatic Peak Integration Function –                                                              This feature helps improve system availability and increases
                                ™
                                                                                                                                        ef ciency.


                     The manual integration of unresolved peaks is a labor-intensive process and prone to inconsistent results depending upon the
                     experience level of the user. Shimadzu’s proprietary i-PeakFinder peak integration algorithm is perfect for such situations.
                     i-PeakFinder processes large volumes of data with high precision in a single step, saving a lot of time and increasing the
                     consistency of results.
                                                                                                                                        Tool-free Column Installation
                         mV                                            mV
                                       Main peak  Impurity                           Main peak  Impurity                                ClickTek  connectors (option) make tool-free column installation a snap. The
                          4                                             4
                                                                                                                                               ™
                          3                                             3                                                               click sensation felt when  nished attaching the column provides a more reliable
                                                                                                                                        connection and ensures a better seal under all operating conditions. In addition,
                          2                                             2                                                               a light has been installed inside the oven to brightly illuminate the area at hand,
                                                                                                                                        easing the burden on the operator when attaching columns.
                          1                                             1
                                                                                                                                                                                                           ClickTek  and Oven Light
                                                                                                                                                                                                                ™
                                                                        0
                          0
                              12.5      15.0      17.5  min                12.5       15.0      17.5  min
                          Baseline processing with no parameters speci ed  Baseline processing with complete separation                 One-touch Inlet Maintenance
                     Compliant with ER/ES Guidelines and Data Integrity  Centralized Management of Data and User Information            The injection port can be opened or closed without tools by simply sliding the
                                                                                                                                        ClickTek lever. Replace the insert, slide the lever and feel the click for a leak-free
                     LabSolutions has a variety of functions to ensure compliance   Data and user information are managed on a database with   install every time.
                     with FDA 21 CFR Part 11 and Japanese Ministry of Health,   restrictions. Fine-grained division of operational restrictions
                     Labour and Welfare guidelines on electronic records and   allows optimum user management based on role, such as
                     electronic signatures. LabSolutions also includes functions that   system administrator, analysis operator, etc.
                     address and support data integrity.
                                                                                                                                                                                                               ClickTek  Nut
                                                                                                                                                                                                                    ™

                     Analysis Starts Immediately under the Optimal Conditions
                                                                                                                                        Preventing Problems and Improving the System Availability Factor
                     – Automatic Start and Stop Functions –

                     When starting and stopping a GC instrument, time is needed for the utility gas supply, oven temperature, and detectors to   Automatic Notification of Replacement Periods  Diagnoses Instrument Operating Status
                     stabilize. When the automatic start and stop function is used, the GC automatically controls the gas and temperature,   – Monitoring Function –                  – Self-Diagnostic Function –
                     enabling the instrument to start up and shut down even when the operator is not present. In addition, continuous
                     instrument operation is avoided, which minimizes running costs.                                                    The Nexis GC-2030 includes various monitoring functions,   The operational status of the instrument can be con rmed
                                                                                                                                        which remind users when to replace consumables and help   using the self-diagnostic (system check) function. Periodic
                                                                                                                                        ensure data quality.                          diagnostics help prevent unexpected downtime.
                                                                                                                                        Power consumption can also be monitored in real time.
                              Stop analysis                                                      Start analysis
                                 10:00  11:00  0:00  1:00  2:00  3:00  4:00   5:00  6:00  7:00   8:00  9:00
                                                                                                                                        Carrier Gas Leak Check Function
                                           Automatically stops                   Automatically starts
                     With auto             gas control                                gas control
                     start/stop      Automatically stops                               Automatically starts                             Check for leakage of gas from the sample vaporization
                                     temperature control                               temperature control
                                                                                                                                        chamber with a single tap.
                                                                                                                                        Checks can be performed with the column attached as is,
                     Without auto                                                                                                       thereby speeding up the procedure.
                     start/stop            Temperature and gas control continue until analysis on the next day



        8                                                                                                                                                                                                                        Gas Chromatograph  9
   3   4   5   6   7   8   9   10   11   12   13