Page 4 - Shimadzu Nexera MX
P. 4

global w430×h280




            Original hardware control technology

            cuts analysis time in half!



            Conventional analysis requires performing various processes such   Therefore, demands have increased for LCMS systems that   Ultra-fast and Ultra-low Carryover Autosampler SIL-40 Series
            as column washing, equilibration at initial mobile phase   shorten the time spent for processes other than data acquisition
            concentrations, and the next sample injection by the   in order to improve analytical throughput.                            High Capacity PLATE CHANGER
            autosampler during the analysis.

                                                                              In an analysis of four biomarker compounds for the
                                    Analysis time
                                                                              four major molecular species in the Cytochrome            Analysis Cycle Time Less Than 10 Seconds
                 Time period to                       Time period to perform  P450 family, the Nexera MX completed the analysis         The SIL-40 autosampler can process the entire injection
                  acquire data                        other processes such as  in only 38 seconds whereas conventional HPLC
                                                      equilibration of columns  required one minute, 22 seconds.                        cycle time in as little as seven seconds, twice as fast as the
                                                                                                                                        previous model. In addition, continuous analysis can be        6.7 sec
                                                                                                                                        carried out on up to 44 MTPs (using 3 PLATE CHANGERS).
                                                                                                                                        Together these features dramatically increase analysis
                                                                                                                                        throughput.
                                                                                                 2 Fold
               Nexera MX                                                                        Throughput
               System


                                                                                                                                                                                                  0.00   0.25   0.50   0.75  1.00   1.25  min
                                                                                                                                                                                                   8 injections can be completed within 1 minute (Caffeine)


                                                                                                                                        Ultra-low Carryover

                                                                                                                                        The Nexera boasts ultra-low carryover, even on a high-sensitivity LC/MS/MS.
                                  38 seconds
                                                                                                                                        This reduces time spent on rinsing, resulting in a shorter overall analysis time.
               Conventional
               HPLC System                                                                                                                       3.0  (x10,000)
                                                                                                                                                 2.5
                                                                                                                                                           Chlorhexidine 500 ng/µL
                                                                                                                                                 2.0
                                     1 min 22 seconds                                                                                            1.5             Blank
                                                                                                                                                 1.0
                                                                                                                                                 0.5
                Nexera MX Dual Stream Technology (MX-DST)                                                                                        0.0
                                                                                                                                                  0.0        0.5        1.0        min
                                                        Drain
                                                                          The MX-DST incorporates a special flow line
                        Analysis
                 Stream 1  Pump               Column                      structure and instrument control system, and
                                                                          performs overlap control of sample injection by
                                   Autosampler           LCMS             using two analysis systems (streams) alternately.
                        Wash / Equilibration                              As a result, after one system completes data
                 Stream 2  Pump               Column                      acquisition, the other system starts data                               3.0  (x1,000)
                                                                          acquisition immediately, making it possible to
                                                        Drain                                                                                     2.5
                                                                          use nearly the whole time of LCMS operation for                         2.0
                                                        Drain             data acquisition.
                        Wash / Equilibration                                                                                                      1.5   Carry over
                 Stream 1  Pump               Column                                                                                              1.0   0.00007%
                                                                                                                                                  0.5
                                   Autosampler           LCMS                                                                                     0.0
                        Analysis                                                                                                                   0.30         0.6         0.9  min
                 Stream 2  Pump               Column                                                                                                                 Rinse Conditions: Normal
                                                        Drain

                                                                                                                                                                                                                           Nexera MX
      4                                                                                                                                                                                                            Ultra-High Speed LCMS System for Multiplex Analysis  5
   1   2   3   4   5   6   7   8