Page 7 - Shimadzu Nexera FV
P. 7

Reliable Performance Expands the Range of Choices  Special Software Enables More Efficient Testing Preparation



 Compatible with High-Concentration Samples Requiring Dilution  DT-Solution Software Supports the Creation and Implementation
                  of Test Schedules
 High dissolution quantity samples often require
 dilution. Samples can be diluted by using the fraction   Dilution Ratio (Times)  Dilution Accuracy (%)  With dissolution tests, one of the most labor-intensive   in a single window. Then, click a single button to
 analysis mode. High injection accuracy is provided   processes is establishing a batch schedule for the test. The   automatically generate a batch schedule in LabSolutions
                                                                                                   ™
 2  100
 even at trace quantities, enabling reliable dilution   custom DT-Solution software eases the burden. With this   software so that testing can start. In dissolution tests
 even without manual handling.  5  100  software, the user can configure all the required information   performed with the Nexera FV, preparation time is minimal.
 The data shows a comparison between a standard
 10  101
 liquid (aqueous caffeine solution), with the dilution
 ratios manually adjusted by an experienced engineer,   20  101
 and a standard liquid automatically diluted by the
 50  101
 Nexera FV. This data shows that the system can
 perform dilution reliably.  100  102





 One System Plays Two Roles, Significantly Improving the
 Throughput of the Testing Lab

 The Nexera FV is a multipurpose system for on-line dissolution testing and high-efficiency UHPLC analysis, such as compound
 screening, and everyday method development applications. This significantly increases the system operation rate in the
 laboratory.






                  Rapid Confirmation of Test Results and Automatic Generation of Reports

               The browser function built into LabSolutions is convenient for   multi-data report function. When the test finishes, a result
               assessing changes in the chromatogram over time. Multiple   table, pivot graphs, and test pass/fail judgments for each
 or            data sets can be displayed simultaneously in a single window,   component are created automatically, so the test results can
               so the data can be compared at a glance. In addition, the
                                                             be rapidly confirmed.
               creation of reports can be completely automated with the









 Long-Lasting Consumables Provide for High Cost-Effectiveness

 A special septum is used for the flow vial that receives the dissolution medium. It boasts a
 better degree of adherence after needle penetration in comparison to a regular septum, and
 can be used for 100 continuous injections without leaking. This greatly reduces maintenance,
 enabling continuous testing.