Page 5 - Shimadzu iSpect DIA-10
P. 5
Unprecedented Functionality and Performance Easy Operation
Trace Sample Measurement Measurement results are obtained in three steps. Pump operation and particle imaging are performed automatically
according to the analytical conditions selected. In addition, particle images can be simultaneously monitored and
The system can measure sample as small as 50 µL, enabling it to handle trace samples. Samples can be set directly onto the measured in real time while the sample ows through the unit.
system using a general disposable pipette tip to transfer a sample from a container. This allows simple operation while
preventing contamination.
① Set sample ② Select analytical conditions ③ Input le name
Flow Path Design Provides Small Dead Volume Set sample with a
micro pipette
Microcells with small internal volumes and small dead volume (less than 50 µL) enable cleaning solution to be reduced.
Reduced Use of Organic Solvents
The ow path has excellent resistance to organic solvents. Because of the small amount of organic solvent needed for
measurement and cleaning, the system reduces waste and minimizes environmental impact.
Sample inlet Real-time
monitoring of
particles during
measurement
Short ow path, small dead volume
Sample setting is completed Display of automatic
by just touching the pipette tip
measurement results
Microcell with small internal volume
(Cell width 1 mm and cell thickness 0.12 mm)
Microcell unit
Autofocus Function for Easy Operation
The autofocus function eliminates the need for troublesome focusing and no ow of sample particles is required. By
automating the focusing, data variation between operators is prevented, making measurement both easy and stable.
Compact, Easy to Install Design
The compact design (the measurement unit is about 22 cm wide and the pump unit is about 10 cm wide) allows
installation in a small space.
Approx. 22 cm
Create a scattergram by Create a histogram
selecting two optional (frequency distribution map)
Approx. 10 cm
measurement items* for any measurement item
* Measurement Parameters (13 Types)
Area circle equivalent diameter, perimeter equivalent diameter,
maximum length, maximum perpendicular length,
vertical Feret diameter, horizontal Feret diameter,
particle perimeter, envelope perimeter, circularity, aspect ratio,
horizontal bounding rectangle aspect ratio, particle area, Thumbnail display of detected particle images
average brightness
Pump unit Measurement unit
iSpect DIA-10
Dynamic Particle Image Analysis System
4 5