Page 5 - Shimadzu iSpect DIA-10
P. 5

Unprecedented Functionality and Performance  Easy Operation





 Trace Sample Measurement  Measurement results are obtained in three steps. Pump operation and particle imaging are performed automatically
                 according to the analytical conditions selected. In addition, particle images can be simultaneously monitored and
 The system can measure sample as small as 50 µL, enabling it to handle trace samples. Samples can be set directly onto the   measured in real time while the sample  ows through the unit.
 system using a general disposable pipette tip to transfer a sample from a container. This allows simple operation while
 preventing contamination.
                       ① Set sample          ② Select analytical conditions  ③ Input  le name
 Flow Path Design Provides Small Dead Volume  Set sample with a
                        micro pipette
 Microcells with small internal volumes and small dead volume (less than 50 µL) enable cleaning solution to be reduced.
 Reduced Use of Organic Solvents

 The  ow path has excellent resistance to organic solvents. Because of the small amount of organic solvent needed for
 measurement and cleaning, the system reduces waste and minimizes environmental impact.

 Sample inlet                                                                                Real-time
                                                                                             monitoring of
                                                                                             particles during
                                                                                             measurement

 Short  ow path, small dead volume




                      Sample setting is completed                          Display of automatic
                     by just touching the pipette tip
                                                                           measurement results
 Microcell with small internal volume
 (Cell width 1 mm and cell thickness 0.12 mm)
 Microcell unit

 Autofocus Function for Easy Operation

 The autofocus function eliminates the need for troublesome focusing and no  ow of sample particles is required. By
 automating the focusing, data variation between operators is prevented, making measurement both easy and stable.

 Compact, Easy to Install Design

 The compact design (the measurement unit is about 22 cm wide and the pump unit is about 10 cm wide) allows
 installation in a small space.




 Approx. 22 cm
                    Create a scattergram by   Create a histogram
                    selecting two optional   (frequency distribution map)
 Approx. 10 cm
                    measurement items*       for any measurement item
                     * Measurement Parameters (13 Types)
                     Area circle equivalent diameter, perimeter equivalent diameter,
                     maximum length, maximum perpendicular length,
                     vertical Feret diameter, horizontal Feret diameter,
                     particle perimeter, envelope perimeter, circularity, aspect ratio,
                     horizontal bounding rectangle aspect ratio, particle area,  Thumbnail display of detected particle images
                     average brightness
 Pump unit  Measurement unit



                                                                                              iSpect DIA-10
                                                                                              Dynamic Particle Image Analysis System
 4                                                                                                                   5
   1   2   3   4   5   6   7   8