Peripheral Equipment Specifications
A Wide Variety of Peripherals Specifications
Accessories that enable automatic analysis and sample introduction at your discretion.
1. Monochromator unit 4. Four flow line gas controller (for plasma)
Autosampler AS-8T Ultrasonic nebulizer UAG-1 Monochromator 1 Plasma gas 0 to 20 2 L/min steps
(P/N 205-04940-02) (P/N 205-09295)
Optical system 1 m Czerny-Turner mounting Auxiliary Gas 0 to 1.4 0.2 L/min steps
No. of diffraction grating grooves 4960 grooves/mm Carrier gas 0 to 1.55 0.05 L/min steps
This type handles both beakers and test tubes. This is a sample injection system developed for
It can be loaded with 100 of the 20 mL test tubes high-sensitivity ICP analysis. Unlike the usual nebulizer Wavelength range 160 to 372 nm Purge gas (Monochromator 1) 3.5 L/min
or 50 of the 30 mL beakers. A table is necessary. that uses the negative pressure of the carrier gas, this Reciprocal dispersion 0.15 nm/mm 5. Data processor (software)
nebulizer uses ultrasonic energy to nebulize a solution.
*Requires interface kit with table (P/N 211-80655). Ultrasonic energy can produce large amounts of Detector Photomultiplier tube OS Windows XP/Windows Vista
extremely fine particles. This enables the UAG-1 to Slit Entrance slit 20 µm No. of measurement Qualitative analysis 1: 72 elements × 1 wavelength
Table size: W600×D600×H690 mm perform analyses at a high sensitivity of 10 to 100 times wavelengths
the sensitivity of conventional nebulizers. Exit slit 30 µm Qualitative analysis 2: 72 elements, maximum 216 wavelengths
AS-8T for organic solvents Size: Main unit W320×D380×H540 mm Exhaust system Rotary pump Quantitative analysis: 72 elements, maximum 72 wavelengths
(P/N 211-48059-01) Power supply: W382×D360×H159 mm With oil backflow prevention valve Database Analyzed wavelengths data: 72 elements, maximum 16 wavelengths
Power supply: Single phase 100 V, 50/60 Hz, 10 A Temperature control Available (±0.1 °C) Wavelength table: Approx. 110,000 wavelengths recorded
*A cooling water system is necessary as a utility. Monochromator 2 Analysis cards 100 cards
Optical system 1 m Czerny-Turner mounting Quantitative analysis Calibration curve sample, maximum 16 samples per card
Hydrofluoric acid sample injection system If water for the cooling system is not supplied from the public water system, No. of diffraction grating grooves 4320 grooves/mm Drift correction
HFS-2 a CA-1112 cooling water circulator and piping kit C are required.
1800 grooves/mm Internal standard correction
(P/N 211-42853-03) Table ND with caster Wavelength range 250 to 426 nm (4320 grooves/mm) Background correction
(P/N 219-96005) (included) Size: W600×D480×H750 mm
Samples composed primarily of silicates, such as 426 to 850 nm (1800 grooves/mm) Blank signal elimination
rocks, soil, cement and ceramics, are insoluble or Reciprocal dispersion 0.17 nm/mm (4320 grooves/mm) Matrix correction
dissolve poorly in strong acids. When hydrofluoric Hydride generator HVG-ICP 0.44 nm/mm (1800 grooves/mm) 6. Safety functions
acid is used to dissolve these samples, normal
injection systems cannot be used as they are (P/N 211-40981) Detector Photomultiplier tube Plasma extinguishment detection Stand temperature check
made of glass. A sample dissolved in hydrofluoric Slit Entrance slit 20 µm Argon gas pressure check High-frequency power supply temperature check
acid can be injected into the plasma directly by The elements within the sample are reduced
using an injection system made of fluorinated and vaporized by the nascent hydrogen Exit slit 30 µm Cooling water circulation check Monochromator vacuum check
ethylene resin.
generated in the decomposition of sodium Light guide Optical fiber Stand door open/closed check Monochromator temperature check
borohydride. Only the gas phase is injected Temperature control Available (±0.1 °C) 7. Autosampler AS-9
into the plasma to achieve measurement with
a high degree of sensitivity. Spectrometer for internal standard method (optional) Any sample is accessible by CPU control
As, Se, Sn, Te, Bi etc. can be measured. Optical system 0.5 m Pachen-Runge mounting No. of samples 50
Peristaltic pump Size: W333×D210×H195 mm
(P/N 204-77310-02) Power supply: Single phase 100 V, 50/60 Hz, 2 A No. of diffraction grating grooves 2700 grooves/mm Sample container 20 mL test tube
*A table ND (with casters) is necessary. Internal standard element Y (371.0 nm) Actuation method X-Y actuation
Used in the analysis of high viscosity samples. Light guide Optical fiber 8. External dimensions Units: mm
A fixed sample injection is possible. Table ND with caster Place of installation Inside thermostatic chamber in Monochromator 1 W1990×D1040×H960 / Weight: Approx. 640 kg
(P/N 219-96005) Size: W600×D480×H750 mm Monochromator controller (installed on respective monochromators 1 and 2)
200
CPU With 32-bit microprocessor
Cooling water circulator CA-1114 Photometric unit (installed on each monochromator)
(P/N 044-01809-07) Negative high-voltage power supply Variable 16 steps
Monochromator for internal standard method Size: W354×D384×H851 mm 41 kg Photometric method Sequential element measurement method 960
Power supply: Single phase 100 V, 50/60 Hz, 15 A
(P/N 205-02165-02) 2. ICP light source
Specifications Piping kit C: UAG-1 only Plasma torch Quartz plasma torch 595
This is installed in the Shimadzu Optical mount: 0.5 m Pachen-Runge mounting Nebulizer Coaxial type, Pyrex glass
sequential plasma spectrometer to No. of grooves in the diffraction grating: (P/N 211-83633-03)
perform simultaneous internal 2700 grooves/mm Piping kit D: AX-3 only Spray chamber Cyclone chamber, Pyrex glass
standard analysis. Internal standard element: Y (371.0 nm) (P/N 211-83633-04) Torch vertical actuation mechanism Computer controlled (11 mm to 25 mm)
Light guide: by optical fiber
*Requires attachment kit Place of installation: Inside thermostatic chamber Piping kit U: AG-1 and AX-3 3. Radio frequency generator
(P/N 211-82923). in Monochromator 1 (P/N 211-83633-05) Oscillator Crystal oscillator
Frequency 27.120 MHz ±0.05 % (ISM band)
Axial attachment AX-3 Low-temperature thermostatic Output 0.8, 1.0, 1.2, 1.4, 1.6, 1.8 kW
(P/N 211-41992) water heater NCB-1200 (SP) Output stability Within ±0.3 %
(P/N 044-01910-01) Radio frequency circuit element Transistor
*A cooling water system is necessary as a utility. Control system CPU control
For the water cooled chamber kit Ignition method Fully automatic ignition
If water for the cooling system is not supplied from
the public water system, a CA-1112 cooling water Size: W210×D430×H639 mm 29 kg With safety function Radio frequency generator temperature fault detection
circulator and piping kit D are required. * Windows is a registered trademark in the United States and other countries of Microsoft Corporation.
Power supply: Single phase 100 V, 50/60 Hz, 9.5 A