Page 8 - Shimadzu HS-20 NX series
P. 8

Beyond Expectation









                     Ultra-sensitive analysis                                                                                           Analysis of extractables and leachables contained in packages


                                                                                                                                        It has been pointed out that there are
                                                                                                                                        safety concerns about extractables and
                                                                          Trace Fragrance Analysis in Spices                            leachables contained in pharmaceutical
                                                                          by HS-20 NX Trap Mode                                         packages and medical devices leaching
                                                 5  6  7  8  9
                             1
                                                                                                                                        into human bodies and medicines. Thus, it
                                            3                  10         In some cases, the HS-20 NX loop model may                    is required to understand residual solvents
                                               4
                                                                  11      not be sensitive enough to analyze trace                      and residual monomers contained in
                                                                          amounts of flavor in food samples like spices.                 polymers. The use of the HS-20 NX trap
                                        2
                      3 Trap
                                                                          The HS-20 NX trap model can concentrate the                   mode and the Xtra Low Bleed HS septa,
                      Loop                                                                                                                                                  TD-30
                                                                          analytes in a sample by using some trap                       which is made of highly heat resistant and
                           5.0    7.5    10.0   12.5   15.0  17.5         materials, which enables ultra-sensitive                      clean material, enables the analysis and   HS-20 NX
                                                                                                                                                                            Trap
                                                                          analysis.                                                     evaluation of extractables and leachables,   HS-20 NX
                      1 Acetic Acid  4 beta. - Pinene  7 gamma. - Terpinene  10 Cuminaldehyde
                                                                                                                                                                            Loop
                      2 2,3-Butanediol  5 D-Limonene  8 Linalool  11 Geranyl acetate
                                                                                                                                        an analysis that is difficult with the loop
                      3 alpha - Pinene  6 m-Cymene  9 Camphor                                                                                                                2.5   5.0   7.5   10.0  12.5  15.0  17.5  20.0  22.5
                                                                                                                                        mode.
                                                                                                                                                                                       Comparative Analysis of Extracts from Eye Drops Caps
                                                                                                                                                                                      (TD-30 vs HS-20 NX Trap mode vs HS-20 NX Loop mode)





                                                                                                                                        Sample enrichment using an electronic cooling trap


                                                                                                                                        The HS-20 NX Trap model includes an electronic cooling trap. Since the HS-20 NX Trap models can be cooled down to
                                                                                                                                        -20 °C or less, it is possible to concentrate and analyze chemicals over a wide boiling range.




                                                                                                                                                                                                         Area  4.5
                                                                                                                                                                                                          4.0  Ethylene
                                                                                                                                                                                                          3.5  Ethane
                                                                                                                                                                                                          3.0  Propane
                                                                                                                                                                                                          2.5
                                                                                        loop model                                                         Ethylene (B.P. -103.7 C)  Ethane (B.P. -89 C)
                                                                                                                                                                                                          2.0
                                                                                                                                                                                                          1.5
                                                                                                                                                                                                          1.0
                                                                                                                                                                                                          0.5
                                                                                                                                                                                                          0.0
                                                                                                                                                                                                            1 Trap  2 Trap  3 Trap  5 Trap
                                                                          With the trap mode of the HS-20 trap model,
                                                                          which can concentrate samples, 10 - 100 times
                                                                                                                                                                                             5 Trap        Trap  Ethylene  Ethane  Propane
                                                                          more sensitive analysis can be achieved than                                                                                     X1    1.0   1.0   1.0
                                                                                                                                                                                             Loop
                                                                          with the loop mode. The HS-20 trap model                                                                                         X2    2.1   2.0   2.0
                                                                          also operates in the loop mode, giving users                                                                                     X3    2.6   2.6   2.7
                                                                                                                                                                                                           X5    4.0   3.7   3.8
                                                                          the flexibility to meet multiple analytical                       1.75  2.00  2.25  2.5  2.75  3.00  3.25  3.5  3.75  4.0  4.25
                                          trap model                      requirements.                                                          Comparison of analysis of 1 ppm of hydrocarbons (loop vs trap x 5)


        8                                                                                                                                                                                                                                    9
   3   4   5   6   7   8   9   10   11   12