Page 15 - Shimadzu HMV-G Series
P. 15
global w430×h280
Specifications
HMV-G31 Series HMV-G30 Series HMV-G31-FA and HMV-G31-XY (HMV-G31 + Electric XY Stage)
Monochrome Camera HMV-G31S HMV-G31D HMV-G30S HMV-G30D Monochrome Camera
without Electric Turret 344-04273-˘˘ 344-04274-˘˘ 344-04271-˘˘ 344-04272-˘˘ without Electric Turret
Monochrome Camera HMV-G31ST HMV-G31DT HMV-G30ST HMV-G30DT Monochrome Camera HMV-G31-FA-S HMV-G31-FA-D HMV-G31-XY-S HMV-G31-XY-D
with Electric Turret 344-04277-˘˘ 344-04278-˘˘ 344-04275-˘˘ 344-04276-˘˘ with Electric Turret 344-04279-˘˘ 344-04280-˘˘ 344-04281-˘˘ 344-04282-˘˘
Model P/N Model P/N
Color Camera without HMV-G31S-HC HMV-G31D-HC Color Camera without
Electric Turret 344-04287-˘˘ 344-04288-˘˘ Electric Turret
Color Camera with HMV-G31ST-HC HMV-G31DT-HC Color Camera with HMV-G31-FA-S-HC HMV-G31-FA-D-HC HMV-G31-XY-S-HC HMV-G31-XY-D-HC
Electric Turret 344-04289-˘˘ 344-04290-˘˘ Electric Turret 344-04291-˘˘ 344-04292-˘˘ 344-04293-˘˘ 344-04294-˘˘
16 stages in total 16 stages in total
9.807 mN, 19.61 49.03, 98.07, 245.2, 490.3, 980.7 mN, 1.96 N, 2.942, 4.903, 9.807, 19.61 N 9.807 mN, 19.61 49.03, 98.07, 245.2, 490.3, 980.7 mN, 1.96 N, 2.942, 4.903, 9.807, 19.61 N
Test Force 12 stages (HV0.001, HV0.002, HV0.005, HV0.01, 0.025, 0.05, 0.1, 0.2, 0.3, 0.5, 1, and 2) Test Force 12 stages (HV0.001, HV0.002, HV0.005, HV0.01, 0.025, 0.05, 0.1, 0.2, 0.3, 0.5, 1, and 2)
plus four user-designated stages *1 plus four user-designated stages *1
Loading Unit Automatic loading and automatic force changing Loading Unit Automatic loading and automatic force changing
Test Force Duration Time User-designated settings from 0 to 999 sec *2 , in 1 sec increments Test Force Duration Time User-designated settings from 0 to 999 sec *2 , in 1 sec increments
Maximum Number of Indenter Attachments 1 2× (1 empty) 1 2× (1 empty) Maximum Number of Indenter Attachments 1 2 1 2
Standard Indenter Provided 7JDLFST *OEFOUFS Standard Indenter Provided Vickers Indenter
Maximum Number of Objective Lens Attachments 2 4 2 4 Maximum Number of Objective Lens Attachments 2 4 2 4
Standard Objective Lenses Provided 40× (1 empty) 40× 10× (2 empty) 40× (1 empty) 40× 10× (2 empty) 40× (Super-long 40× (Super-long
Automatic readings via digital image analysis, and manual Standard Objective Lenses Provided Working Distanse) Working Distanse) 40× (1 empty) 40× 10× (2 empty)
Indentation Reading System Manual readings via an optical microscope 5× (0 empty) 5× (2 empty)
settings for line length measurement in the PC window
Automatic readings via digital image analysis,
Eyepiece ×10 Indentation Reading System
and manual settings for line length measurement in the PC window
USB Connection (USB 2.0) Eyepiece
1/3-inch image size
Monochrome
Measurement image 640 × 480 pixels USB Connection (USB 2.0)
Digital Camera 256 tint gradations (digital image data) Monochrome 1/3-inch image size
Measurement image 640 × 480 pixels
USB Connection (USB 3.0 Super Speed) 256 tint gradations (digital image data)
Color 2/3-inch image size Digital Camera
Measurement image 2448 × 2048 pixels USB Connection (USB 3.0 Super Speed)
Color 2/3-inch image size
Effective Measurement Range Monochrome Camera: 120 × 90 µm Measurement image 2448 × 2048 pixels
(For 40× objective lens) Color Camera: 195 × 160 µm 250×250µm
Effective Measurement Range Monochrome Camera: 120 × 90 µm
Area: 100 × 100 mm; Stroke: ±12.5 mm; Sample: Maximum height 100 mm (For 40× objective lens) Color Camera: 195 × 160 µm
Instrument’s lateral direction (width direction): Unlimited *3 ;
Instrument’s depth direction: Unlimited for samples with a width of 120 mm max. *3 Area: 125 × 125 mm; XY Axis Stroke: ±25 mm; Sample: Maximum height 65 mm
XY Stage
When sample width is greater than 120 mm: 200 mm max. *3 Instrument’s lateral direction (width direction): Unlimited
Z Axis Stroke: 60 mm; Spacer provided: Thickness 40 mm; Maximum Loading: 10 kg XY Stage Instruments depth direction: Unlimited for samples with a width of 120 mm max. *3
The center of gravity of objects loaded must be located on the stage. When sample width is greater than 120 mm: 175 mm max.
Z Axis Stroke: 45 mm; Spacer provided: Thickness 30 mm
Autofocus Function Note: There is also a large sample stage edition with an area of 200 × 200 mm and an XY axis stroke of ±60 mm.
Pattern Settings Items
Autofocus Function Y N
Image Acquisition Functions Linear division, linear pitch, matrix, rectangular division, rectangular pitch, square, circular division,
ᶃ Vickers Hardness HV ᶄ Knoop hardness HK *4 ᶅ Brinell hardness: HB *4 ᶆ Triangular Pyramid Hardness HT *3 Pattern Settings Items circular pitch, arbitrary, zigzag
ᶇ Length, direct reading L (µm) *5 ᶈ Fracture Toughness Kc
Data Processing Functions Image Acquisition Functions Total image acquisition function and edge detection function
ᶉ Shape correction function (cylindrical surfaces and spherical surfaces)
Note: The cracks for measuring fracture toughness are determined manually by the operator. ᶃ Vickers Hardness HV ᶄ Knoop hardness HK *4 ᶅ Brinell hardness: HB *4 ᶆ Triangular Pyramid Hardness HT *3
Data No., diagonal line length, hardness, conversion value, average, standard deviation, Data Processing Functions ᶇ Fracture Toughness Kc ᶈ Shape correction function (cylindrical surfaces and spherical surfaces)
Displayed Items Note: The cracks for measuring fracture toughness are determined manually by the operator.
Results Displayed coefficient of variation, maximum value, minimum value, pass/fail determination
Graphical Display Variance graph, depth of hardening graph *6 Variance graph, histogram, depth of hardening graph *6 Displayed Items Data No., diagonal line length, hardness, conversion value, average, standard deviation,
USB Transfer of test results to a USB flash drive (CSV format) Results Displayed coefficient of variation, maximum value, minimum value, pass/fail determination
External Output 5IFSNBM QSJOUFS Graphical Display Variance graph, depth of hardening graph *6
Printer Printer output from a PC via software
$PNQBUJCMF XJUI MBTFS QSJOUFST External Output USB
External Dimensions Approx. W350 × D570 × H540 mm Printer Printer output from a PC via software
Weight "QQSPY LH External Dimensions Approx. W350 × D570 × H540 mm
Weight Approx. 50 kg
Main unit: Single-phase 100 to 115 VAC, 230 VAC, 100 VA (50/60 Hz)
Power Supply Note: Prepare a grounded outlet. (D type ground, with a ground resistance of 100 Њ max.) Main unit: Single-phase 100 to 115 VAC, 230 VAC, 100 VA (50/60 Hz)
Note: With the HMV-G31 series, a power supply for the PC will be required in addition to the above mentioned. Power Supply Motor Control Box: Single-phase 100 VAC, 100 VA (50/60 Hz)
Note: Prepare a grounded outlet. (D type ground, with a ground resistance of 100 Њ max.)
OS: Windows ® 10 (64 bit edition) Note: A power supply for the PC will be required in addition to the above mentioned.
CPU: Intel Core ™ i5-6500 or faster
®
*8
USB Ports : For monochrome camera OS: Windows 10 (64 bit edition)
®
PC Provided *8 Uses two USB 2.0 or 3.0 ports CPU: Intel ® Core ™ i5-6500 or faster
For color camera USB Ports: For monochrome camera
Uses one USB 3.0 port (required) and PC Provided *8 Uses two USB 2.0 or 3.0 ports
one USB 2.0 or 3.0 port
For color camera
*1) An arbitrary test force can be configured in the range of 9.807 mN to 19.61 N, in increments of the minimum 9.807 mN (HV 0.001). Uses one USB 3.0 port (required) and one USB 2.0 or 3.0 port
*2) When performing tests with the retention time set to 60 seconds or longer, turn ON the instrument at least 30 minutes before starting the test.
*3) The width of open space in the instrument’s depth direction is approximately 140 mm. *5) The direct length reading is only available with HMV-G30 series.
When testing samples with a width of 120 mm or less and a depth of 175 mm or more, give consideration to the required movement range of the XY stage, *6) Depth of hardening graphs can only be displayed when the digital micrometer (optionally available) is used.
and ensure that the width of the open space is not exceeded. *7) The set items with the PC provided by Shimadzu is recommended.
Ensure that the shape of the sample is such that it is stable when placed on the XY stage. *8) Another USB 2.0 or 3.0 port must be added if using the electric micrometer kit.
*4) The Knoop indenter, Brinell indenter and triangular pyramidal indenter are optional. The Brinell hardness and triangular pyramidal hardness are only read Connect the electric micrometer kit to a USB 2.0 port when using it with a color camera type unit.
in manually.
HMV-G
Micro Vickers Hardness Tester
14 15