Page 4 - Shimadzu DSC-60 Plus Series
P. 4

Diverse Measurements by Simple Operations






            The DSC-60 Plus series features a cooling chamber as standard.
            Measurements below room temperature can be performed by
                                                                        It's easy.
            pouring liquid nitrogen through the inlet into the chamber to   You only need
                                                                      liquid nitrogen
            lower the temperature. This is extremely convenient, as it
                                                                        to run the
            eliminates the need to install special accessories. It achieves  measurements.
            10 ºC/minute performance at −100 ºC, which is adequate for
            measurements during a controlled cooling process.
                                                     Temp
                                                     ˚C
                     21˚C
                                                     0.0
                                                                                                     No need to
                              −50˚C
                                                                                                      install any
                                                                                                     accessories.
                                                     −50.0
                                    −100˚C
                                    (−10˚C/min)
                                                     −100.0
                                                −140˚C
                                                     −150.0
                   -0.0   2.0    4.0    6.0    8.0
                                 Time [min]
                      Cooling Performance with Liquid Nitrogen

            While running a series of analyses below room temperature, the   Temperature  Hold at sample loading temperature
                                                                                      (put in the sample)
            furnace temperature has to be returned to near room   Sample loading
            temperature during sample replacement.                temperature
            The sample loading temperature function heats only the region   Room temperature   Heating (cooling) according to
                                                                                               prescribed program
            around the sample when the sample is replaced, so that
            measurement can be rapidly resumed without moisture    Rapid heating
            condensation.                                                                    Start measurement
                                                                         −150˚C
                                                                                                   Time
                                                                        Sample Loading Temperature Function
            Eco-Friendly

            The newly designed furnace unit reduces energy consumption by over 20 % when heating from room temperature to 300 ºC at a
            20 ºC/minute heating rate (compared to previous Shimadzu instruments). When making measurements below room temperature,
            the liquid nitrogen consumption savings exceed 30 % (compared to previous Shimadzu instruments). The instrument footprint has
            also been minimized.


            DSC-60A Plus Automatic Differential Scanning Calorimeter
            Capable of Continuous Unattended Measurement

                                              The built-in compact autosampler permits automated
                                              measurement, analysis, and report printout for up to 24 loaded
                                              samples. It improves the efficiency of screening during product
                                              development and the efficiency of quality control activities. The
                                              footprint is the same as the standard model.