Page 2 - AXIMA Performance
P. 2

AXIMA Performance™ -

                  the Next Generation in MALDI CID MS/MS


                  A high performance MALDI-TOF-TOF              Essential features providing
                  mass spectrometer utilizing state-of-the-     confident results
                  art high-energy MS/MS, delivering
                  unparalleled flexibility, in a robust and     This next generation design MALDI system delivers all of
                                                                the features expected of an AXIMA series mass
                  reliable research grade system.
                                                                spectrometer:
                                                                • High resolution MS data in reflectron mode for more
                                                                  accurate and confident analysis
                                                                • Uncompromized linear mass range and sensitivity
                                                                • Near-axis laser irradiation for enhanced ion
                                                                  transmission and sensitivity in all modes of operation
                                                                • Advanced calibration algorithms with easy-to-use
                                                                  software providing more accurate data
                                                                • Intuitive software incorporating data-dependent
                                                                  workflows for achieving the maximum result with the
                                                                  minimum user input, making it ideal for novice and
                                                                  expert users alike
                                                                • Flexibility – this is a true workhorse. Polymers,
                                                                  oligonucleotides, SNPs, metabolites, carbohydrates and
                                                                  small molecules amongst others may all be analyzed
                                                                  and processed.

                                                                Advanced MS/MS performance

                                                                The monoPULSE™ high performance, revolutionary ion
                                                                gate provides outstanding MS/MS precursor ion selection
                                                                resolution. When complex mixtures are analyzed, the
                                                                high resolution ion gate allows optimal isolation of ions
                                                                with similar nominal mass, affording successful
                                                                separation of MS/MS fragmentation patterns, producing
                                                                more and higher confidence identifications. Resulting
                                                                MS/MS spectra are easier to interpret and significant
                                                                database search hits are more readily achieved. The
                  • Highest energy collisions – CID with a laboratory frame  high-energy collisions, together with the curved field
                    collisional energy of 20 keV                reflectron (CFR) produce well-balanced, information-rich
                  • Outstanding sensitivity – uncompromised design,  MS/MS data.
                    to ensure no MS/MS signal is discarded      • The unique combination of the advanced curved field
                  • Low sample consumption – allowing many more   reflectron design and the high-energy collision cell
                    MS/MS experiments to be performed on the same  means that all fragment ions formed are detected,
                    sample spot                                   regardless of where they are formed in the instrument.
                                                                  Both LID and CID ions are accumulated into a seamless
                  • Variable repetition rate laser
                                                                  spectrum providing the best possible MS/MS sensitivity.
                  • Optimal precursor ion selection resolution using
                                                                • The Low Mass Zoom™ (LMZ) feature allows rapid
                    revolutionary ion gating technology
                                                                  enhancement of the region of the spectrum
                  • Manual or fully automated operation allowing the  encompassing the immonium ions and isotopically
                    seamless analysis of as few or as many samples as  labelled quantitative diagnostic ions.
                    required
                                                                • Gridless ion path, unique to leading MS/MS systems,
                  • Fully enabled for protein identification –
                                                                  designed to avoid unwanted ion scattering and ensure
                    Intellimarque™ software suite for automated
                                                                  the highest possible ion transmission.
                    data-dependent peptide mass fingerprinting and
                                                                • High sensitivity allowing multiple MS/MS acquisitions on
                    MS/MS of peptides with optional incorporated
                                                                  the same sample spot through low sample consumption.
                    Mascot® database searching
                  • LC-MALDI software allowing confident identification of
                    off-line separated complex mixtures via automated
                    MS/MS
   1   2   3   4   5   6