Page 5 - Kubota - 7000
P. 5

Stainless Steel Bottles


              Use of full capacity of the bottle is possible. Leakage prevention with
              sealing caps
             ・ A wide mouth bottle makes sample collection easy.
             ・ Made of chemical-resistant and durable stainless steel.
             ・ Can be used at high RCF.










                             Autoclavable                                        Autoclavable
                           (supporter is not autoclavable)  Autoclavable       (outer cap is not autoclavable)
                        250mL                     500mL                     1,000mL
                        Code No.052-0050          Code No.052-0060          Code No.052-7080


             Compact design to make the best use of laboratory

             The widths of centrifuges are 64cm and 50cm, which can secure space of laboratory.







                                               86cm                             85cm






                                              82cm                             78cm

                              64cm                               50cm
                               Model 7000                        Model 6000

          ■ Simple operation panel with knobs and keys
             Speed, time and temperature can be set by just turning knobs.










          ■ Function to correct temperature of rotor           ■ Reminder function to prevent
             Temperature of sample turns to the setting           you from leaving the samples in a
             temperature.                                         centrifuge

          ■ Pre-cooling function                                  Buzzer sounds when samples are left behind in the
             Rotor pre-cooling enables rotors to reach low        centrifuge
             temperatures quickly
                                                               ■ Function for operational supervision
          ■ Memory flashing function (patented)                   Data about speed, temperature and time can be
             The duration of the spin-down operation can be       output to the computer.
             memorized automatically.                          ■ Function to adjust curve of
          ■ Integrator function (g・sec value)                     acceleration and deceleration
             for measuring and calculating total               ■ Automatic rotor identification
             centrifugal force                                    The rotor type and maximum speed are
                                                                  automatically identified when the rotor is mounted.