Page 30 - Food&Beverages Solution Palm Oil
P. 30
Liquid Chromatograph Triple Quadrupole
Mass Spectrometer (LC/MS/MS) LC-GC-Online System
Shimadzu Liquid Chromatograph Triple Quadrupole Mass Spectrometer Product Lineup Shimadzu’s MOSH/MOAH analyzer puts manufacturers of food and food packaging on the safe side. The MOSH/MOAH analyzer has
been designed specifically for sensitive and fast detection of mineral oil contaminations based on the draft version of the European Norm
Model Features 16995:2016. The system combines LC and GC technology with flame ionization detection (FID) for a highly efficient analysis covering
preparation, pre-separation and automated processes.
· Ultrafast MRM transition speeds up to 555 MRMs per second are achieved by Shimadzu’s UFsweeper™
collision cell technology
· Fast polarity switching at 15 msec
· MRM optimization in Shimadzu’s LCMS systems requires only minutes to perform.
· Optimized MRM parameters can be transferred, making it possible to transfer methods between systems.
· Easy maintenance
· Wide range of pre-configured MRM Method Packages is available
LCMS-8040
· Equipped with a heated ESI probe
· Provides accurate and stable data over long periods of time
· World's fastest scan speed (30,000 µ/s) and polarity switching time (5 ms)
· Optimized MRM parameters can be transferred, making it possible to transfer methods between systems.
· Easy maintenance
· Wide range of pre-configured MRM Method Packages is available
LCMS-8045
· High sensitivity: S/N > 60,000:1 (RMS)
· High-speed scanning (30,000 µ/s) ultrafast polarity switching time (5 ms)
· Ultrafast MRM transition speeds up to 555 MRMs per second are achieved by Shimadzu’s UFsweeper™
collision cell technology
· Optimized MRM parameters can be transferred, making it possible to transfer methods between systems.
· Easy maintenance
· Wide range of pre-configured MRM Method Packages is available
LCMS-8050
Chromatogram of MOSH/MOAH in food and food packaging
· High sensitivity: S/N > 750,000:1 (RMS)
· High-speed scanning (30,000 µ/s) ultrafast polarity switching time (5 ms)
· Ultrafast MRM transition speeds up to 555 MRMs per second are achieved by Shimadzu’s UFsweeper™ Reference: MOSH/MOAH analyzer for food and food packaging
collision cell technology
· Optimized MRM parameters can be transferred, making it possible to transfer methods between systems.
· Easy maintenance Shimadzu LC-GC Chromatograph Product Lineup
· Wide range of pre-configured MRM Method Packages is available
LCMS-8060 Model Features
· Simultaneous and fast determination of MOSH and MOAH in just 30 minutes.
· Standard sample preparation steps such as solid phase extraction or manual purification are no longer
required.
· Sensitive determination for the most effective detection of MOSH and MOAH levels in food and food
packaging is possible.
· High levels of reproducibility and accuracy
· Combination of LC-GC offers routine, capable methods
Solutions for Palm Oil Analysis Application Notebook
30 31