Page 4 - GC-2050
P. 4

Compact without Compromise







                                                                                                                                                                                           Even if the Brevis GC-2050 does not have a
                     Space-saving yet expandable design
                                                                                                                                                                                           monitor, the GC Remote Display* on your smart
                                                                                                                                                                                           device or PC can be used to check instrument
                     The compact Brevis GC-2050, with a 350 mm system
                                                                                                                                                                                           status, manage daily maintenance procedures,
                     width, including an auto-injector (AOC -30i), makes
                                                  ™
                                                                                                                                                                                           watch videos, etc.
                     even more use of lab space. Compared to the
                                                                                                                                                                                           Note: Windows ®  device application, wired connection to GC is
                     flagship Nexis  GC-2030, the system's width has                                                                                                                            recommended.
                               ™
                     been reduced by approximately 35 %. At the same
                     time, it is possible to connect additional headspace
                     samplers, a mass spectrometer, and other accessories
                     (available soon), providing the scalability to cover                                                               Compact and easy to maintain
                     the analytical needs of today's GC/GCMS users.


                                                                                                                                                                                           One-touch inlet maintenance
                                                                                               350 mm
                                                                                                                                                                                           The injection port can be opened or closed
                                                                                          553 mm
                                                                                                                                                                                           without tools by simply sliding the ClickTek  Nut
                                                                                                                                                                                                                            ™
                             Oven duct                                                                                                                                                     lever. Replace the insert, slide the lever, and feel
                                                       Flow controller/                                                                                                                    the click to ensure leak-free performance.
                                                       AFC,APC(Max5)

                                H2 sensor available
                                                                          Compact system configuration                                                                                     Fast inlet maintenance, Easy sTop

                         INJ(Max2)                                        During development of the Brevis GC-2050,                                                                        Clicking the Maint. (Maintenance) button on the
                         Dual line capable  DET(Max3)
                                                                          the injection ports, detectors, electrical                                                                       GC front will start lowering the temperature of the
                                                                          boards, etc. were rearranged to achieve a                                                                        GC inlet and oven, and stop the gas supply
                                                                          flexible system configuration while                                                                                automatically*. After maintenance of the inlet,
                                                                                                                                                                        MAINT.
                                                                          maintaining a slim system width.                                                                                 clicking the button again will return the instrument
                                                                                                                                                                                           to standby after an automatic leak check. Routine
                                                                                                                                                                                           maintenance procedures can be further simplified.
                                                                                                                                                                                           Note: Disabling the automatic gas supply shutdown to protect
                                                                                                                                                                                               the MS detector is possible.

                                                                                                                                                                                                Cooling      Replace    Setting up
                                                                                                                                                                                         MAINT.                    MAINT.
                                                                                                                                             GAS CHROMATOGRAPH
                                                                                                                                                                                             Click                    Click
                                                         Enough storage for two columns
                                                                                                                                                                                           Tool-less column installation


                     Sufficient GC oven size                                                                                                                                               The ClickTek makes column attachment a
                                                                                                                                                                                           one-touch operation. A noticeable clicking
                     Despite its space-saving design, this GC oven does                                                                                                                    sensation signals a secure column connection,
                     not require a dedicated column, and up to two                                                                                                                         putting the user at ease.
                     general capillary columns can be used.                                                                                                                                Note: The ClickTek connector is optional.




        4                                                                                                                                                                                                                                    5
   1   2   3   4   5   6   7   8   9