P. 5

Electricity, Electronics,  Band Gap Measurements for            Window Glass Transmittance
             and Optics           Semiconductors                 Construction  Measurements
            The diffuse re ection spectra for two types of semiconductors (red line:   Two types of window glass were measured utilizing the ISR-2600Plus
            Culn 0.5 Ga 0.5 Se 2 , blue line: CulnSe 2 ) used as solar cell materials have been   integrating sphere. The sample shown by the red line is highly
            measured using the ISR-2600Plus integrating sphere. It is evident that the   transparent to near-infrared light at 800 nm or more.
            absorption edge (position where the re ectance drops) differs depending       The sample shown by the blue line, however, is apparently not very
            on the sample. This difference signi es a difference in the band gap* for   transparent to near-infrared light.
            these samples. (The samples were provided by Wada Laboratory, Faculty
            of Science and Technology, Ryukoku University.)
                The band gaps for the samples were calculated utilizing the Tauc
            method. The results obtained were 1.27 eV for Culn 0.5 Ga 0.5 Se 2  (red line)
            and 0.99 eV for CulnSe 2  (blue line).
            * The term band gap refers to the energy difference between the top of the valence
             band, which is full of electrons, and the bottom of the conduction band, which does
             not contain electrons.













             Chemicals  Thickness Measurements of Cling Films    Textiles  Evaluation of CNF

            Undulating interference waveforms sometimes occur if light is passed   An ISR-2600Plus integrating sphere was used to measure the total
            through a  lm. The  lm thickness of a sample can be determined by   transmittance spectrum of cellulose nano ber (CNF). Depending on the
            using these interference waveforms. The black line shows transmittance   raw materials used, spectra can vary, transparency can vary, and spectral
            data for polyvinylidene chloride  lm, the red line for nylon  lm, and the   tendencies in the ultraviolet region can vary.
            blue line for polypropylene  lm.
                By using the optional thickness calculation software, the interference
            waveforms were calculated to be 10.0  m, 17.0  m, and 21.4  m,
            respectively.
                                                                          Transmittance
            (Caution) The sample’s refractive index must be entered for the  lm thickness
            calculation.



                                                                                      Wavelength








             Life Sciences  DNA and Protein Measurements         Foods  Vitamin Measurements
            The red and blue lines are the absorption spectra for dsDNA and BSA   This shows the absorption spectra for ribo avin (vitamin B 2 ). The sample
            (bovine serum albumin), respectively. The concentration values are 45   concentrations are, in order from the highest absorbance, 0.08, 0.04,
            ng/ L for dsDNA and 2.2 mg/mL for BSA.             0.02, and 0.01 mg/mL.













                                                                                       UV-2600i/UV-2700i
                                                                                                    UV-VIS Spectrophotometer  5