Applications                                                                                                              Accessories





            Foods                                                     1.00                                                            Expanded Memory                 (P/N 207-23119-41)  Test Tube Holder               (P/N 207-23510-41)

            This is an example of the analysis of food dyes. By using   0.80                                                          The UV-1900i main unit can store up to 999 sets of data.  Holds test tube instead of
            ultra-fast scan mode, the time needed for routine spectral                                                                The saved data can be read out from a PC.          sample compartment.
                                                                      Absorbance (Abs.)  0.40                                         Film Holder                        (P/N 204-58909)  Height: 75 to 115 mm
            checks can be shortened. The 350 nm to 900 nm region can be   0.60                                                        (A network connection is required for data readout.)  Specifications:
            measured at 1 nm intervals in approx. 4 seconds.                                                                                                                              Outside diameter: φ15 to 22 mm


                                                                                                                                      Used in transmittance                               Note: Test tube is not included.
                                                                      0.20                                                            measurement of thin samples
                                                                                                                                      such as films and filters. It                      Multi-Cell Sample Compartment   (P/N 206-69160-41)
                                                                                                                                      holds the samples for
                                                                      0.00
                                                                        350 400        600         800  900                           analysis.                                          Holds up to six 10-mm square
                                                                                    Wavelength (nm)                                                                                      cells on the sample side. No
                                                                              Absorption Spectra of Food Dyes
            Pharmaceuticals and Life Sciences                                                                                                                                            temperature control capability.
                                                                                                                                      Long-Path Rectangular Cell Holder  (P/N 204-23118-01)  Number of cells: 6 on the sample side
            This is an example of the analysis of λDNA. Trace quantities (on
                                                                  1.2                                                                 Holds two rectangular cells with an optical                                   1 on the reference side
            the order of a few µL) can be measured by combining the     Optical path length: 1 mm                                     path length of 10, 20, 30, 50, 70, or 100 mm.      Note: Square cells are not included, please purchase separately.
                                          ®
            instrument with Nano Stick and TrayCell .             1.0          Black: 500
                                                                               Red:    250
            Using TrayCell, a calibration curve for 4 µL of λDNA was           Blue:   100                                            Sipper Unit
                                                                               Green:  50
            obtained in the range between 25 ng/µL and 500 ng/µL.              Orange: 25   1.2  Calibration Curve                                  Model                   P/N     Standard Sample Volume
                                                                 Absorbance (Abs.)  0.5    1.0                                         Sipper Unit 160L (Standard Sipper)   206-23790-51  2.0 mL
                                                                               Unit: ng/µL
                                                                                                                                                                                        1.5 mL
                                                                                                                                                                         206-23790-52
                                                                                                                                       Sipper Unit 160T (Triple-Pass Sipper)
                                                                                           Absorbance (Abs.)  0.5                      Sipper Unit 160C (Constant-Temperature Sipper)   206-23790-53  2.5 mL
                                                                                                                                                                                        0.5 mL
                                                                                                                                                                         206-23790-54
                                                                                                                                       Sipper Unit 160U (Supermicro Sipper)
                                                                                                                                      Four types of sipper units with different flow cells are available. The
                                                                                                                                      stepping motor-driven peristaltic pump ensures reliable and smooth   Note:  The use of a Solenoid Valve (Fluoropolymer) (P/N 204-06599-01)
                                           Nano Stick
                                                                  0.0                      0.0                                        aspiration of sample solution.                         and the SWA-2 Sample Waste Unit (206-23820-58) are
                 TrayCell
                                                                  220   250       300  330  25.0 100.0  300.0  500.0                  (Direct driving is possible from the UV-1900i so no interface is required.)  recommended when strong acids, strong alkalis, or organic
                                                                         Wavelength (nm)        Concentration (ng/µL)                                                                        solvents are to be measured.
                                                                                                                                      CPS-100 Cell Positioner, Thermoelectrically
            Chemistry                                                                                                                 Temperature Controlled          (P/N 206-29500-41)
            This is an example of the analysis of colored cellophane tape.                                                            This attachment permits measurement of up to six sample cells under   TCC-100 Thermoelectrically Temperature
            Materials can be confirmed quantitatively by using LabSolutions                                                           constant-temperature conditions. Combination of this attachment and   Controlled Cell Holder   (P/N 206-29510-41)
            UV-Vis and color measurement software.                                                                                    the Kinetics mode provides measurement of temperature-sensitive
                                                                                                                                      enzyme kinetics of one to six samples.             Uses Peltier effect for controlling the sample and reference
                                                                                                                                                                                         temperature, so no thermostated bath or cooling water is required.
                    100                                          0.90
                                                                                                                                       Number of cells: 6 on the sample side (temperature-controlled)
                                                                 0.80                                                                                            1 on the reference side (temperature not controlled)  Number of cells: One each on the sample and reference sides
                     80                                          0.70                                                                  Temperature control range: 16°C to 60°C            (temperature-controlled)
                                                                 0.60                                                                  Temperature display accuracy (difference from the true value): ± 0.5°C  Temperature control range: 7°C to 60°C
                    Transmittance (%)  60                       y  0.40                                                               Note: Square cells (P/N 200-34442) are not included, please purchase   ± 0.5°C
                                                                                                                                                                                          Temperature display accuracy (difference from the true value):
                                                                                                                                       Temperature control precision (variation of temperature): ± 0.1°C
                                                                 0.50
                                                                                                                                       Ambient temperature: 15°C to 35°C
                                                                                                                                                                                          Temperature control precision (variation of temperature): ± 0.1°C
                                                                 0.30
                     40
                                                                                                                                          separately.
                                                                 0.20
                                                                                                                                          A USB adapter CPS                              Note: Square cells (P/N 200-34442) are not
                                                                                                                                                                                             included, please purchase
                     20                                          0.10                                                                     (P/N 206-25234-91)
                                                                 0.00                                                                                                                        separately.
                                                                   0.00  0.10  0.20  0.30  0.40  0.50  0.60  0.70  0.80                   is required.
                      0                                                               x
                      380      500    600     700   780
                                  Wavelength (nm)
                     Transmittance Spectra of Colored Cellophane Tape   Chromaticity Diagram of XY Color System
                                                                                                                                                                                                                              UV-1900i
      10                                                                                                                                                                                                                      UV-VIS Spectrophotometer  11
   5   6   7   8   9   10   11   12   13   14   15