Page 2 - Shimadzu USF-2000A
P. 2

Powerful Accelerated Testing of Materials Fatigue Strength





            Complete service life of 10  cycles …
                                                   10
              … within 6 days.

            The USF-2000A very high cycle fatigue testing system provides the most time- and cost-efficient test
            procedure for reliable service life data.


            Within just 6 days instead of at least 1 year, the USF-2000A gives information and certainty about the
            loading capacity of metallic and other materials.
            Applying 20 kHz cycle frequency, it completes 10  cycle tests more than 60 times faster compared to 300 Hz.
                                                         10

            For automotive, aerospace and railway applications in particular, the reliability of materials has to be
            predictable to provide best quality and highest safety for consumers and peace-of-mind for manufacturers.


            The USF-2000A generates stress amplitude in a specimen by resonating it with 20 kHz longitudinal wave
            oscillation. It measures 10  to 10  fatigue strength, where it has been difficult or impossible to obtain
                                            10
                                     9
            data previously. Data for 10  can be generated in about 10 minutes.
                                      7



            Day1
               Set up test                              Start test
             Start material characterization by providing material   After selecting the test-type between normal or intermittent driving,
             name, Young’s modulus and material density.    the test can be started.
             Select specimen shape.                   A specified oscillation and stop time (pulse-pause) ratio can be selected in the software.
                                                      Supported by an air-cooling system, it avoids overheating of the specimen.
             Based on the settings, the software generates
             a technical drawing of the specimen automatically.   On reaching the specified number of cycles or exceeding of fluctuation band of
                                                      test frequency due to fatigue crack initiation, the test ends automatically.
             FEM skills are not required.


              Principles                                          (1) Oscillation of piezo actuator in 20 kHz

                                                                  (2) Expanding the amplitude by horn resonance
                                                                  (3) Maximum stress is applied to center because of
                                                                     the specimen resonance in 20 kHz








                                                                    Compression  Neutral  Tensile



                   Specimen                                                                   Center

                                              Displacement  Stress
                                              distribution distribution
   1   2   3   4