Page 4 - Shimadzu PDA-7000
P. 4

Features of the PDA-7000 Series






            High-sensitivity Analysis of Nitrogen in Steel                                                                            New Chassis Case Design offers Superb Environmental Resistance

            Due to the significant effects of nitrogen on the mechanical   limit of 5ppm. This instrument reduces sampling operations   The newly designed chassis case enhances environmental   mounted against the wall to save space. The functional design
            properties of steel, the rapid measurement of nitrogen during   and shortens analysis times. Additionally, it eliminates sample   resistance.                                allows maintenance access from the front.
            the manufacturing process is highly desirable.     defects and enhances yields through its ability to control             The monochromator is made of materials resistant to the effects   The chassis case design offers greater freedom in analysis
            The PDA-7000 has recently been developed to replace gas   nitrogen in cast iron.                                          of temperature fluctuations and is installed in a   laboratory layout.
            analyzers for in-furnace analysis. It achieves a lower detectable                                                         constant-temperature chamber.
                                                                                                                                      The popular compact design is retained. The chassis case can be


            Sensitive Analysis of Trace Elements in Steel
                                                                                                                                      Vacuum Monochromator
            The establishment of manufacturing technologies for high-purity   The PDA-7000 meets these needs by permitting quick and easy
            iron demands process control at lower trace levels of elements,   ppm-level analysis by time-resolution PDA photometry.   The monochromator must be held in a vacuum or in a   Shimadzu adopts a vacuum monochromator that is resistant to
            including C, P, and S.                                                                                                    gas-replacement atmosphere to avoid effects due to the   the effects of temperature fluctuations. It is installed in a
                                                                                                                                      absorption of spectral lines such as C, P, S, B, and N by   temperature-controlled monochromator chamber to achieve
                                                                                                                                      atmospheric oxygen.                                extremely stable measurements.
            Elimination of Contamination Effects

            Replaceable units in the new spark stand eliminate to the   This effectively eliminates effects from the analysis of aluminum   Select Optimal Discharge Conditions to Suit Analysis Range and Elements
            maximum degree effects from high-content sample analysis   alloys when high-purity aluminum is analyzed, for example.
            during trace-element analysis.                                                                                            Several separate discharge types are available for each analyzed   Used with time-resolution photometry, these settings achieve high
                                                                                                                                      element: high-energy discharge, spark discharge for excellent   analysis accuracy.
                                                                                                                                      reproducibility, and arc-like spark discharge for high sensitivity. A   The addition of the optional small-sample analysis kit (page 12)
            New Spark Stand Enhances Stability                                                                                        combination of these can also be selected to set the optimal   permits measurements on 0.01mm-thick samples and
                                                                                                                                      discharge conditions.                              small-diameter samples.
            The structure and materials of the conventional spark stand have
            been upgraded to considerably enhance analysis accuracy for
            high-concentration elements (stainless steel and aluminum alloy).                                                         User-friendly Software
            It accepts large sample plates, offers greater ease of handling, and
            enhances durability.                                                                                                      The software was designed for process analysis, with due   process analysis.
            Further, selecting the optional stand water-cooling kit (see page                                                         consideration of the situation at sites where metals analysis is   Simply enter the required information in sequence to easily create
            12) restricts the spark stand temperature rise due to electrical                                                          conducted in Japan. After the instrument is started, only one   the analysis information.
            discharge during continuous analysis, thereby enhancing the                                                               action is required to enable measurement and allow simple
            stability of the measured values.
                                                                                                                                      Extremely Simple Operation
                                                                                                        Spark Stand
                                                                                                                                      Simply mount a sample in the spark stand, enter the sample   depends on the analysis conditions.)
                                                                                                                                      number, and press the start button to display the analysis results   The analysis data can be easily converted for flexible processing by
            Electrode Cleaning Extends Electrode Life approx. 10 Times                                                                on the screen in just over ten seconds. (The actual analysis time   commercial software.

            Electrode life is increased by approximately ten times by adopting   electrode-cleaning unit (page 12) can be selected to keep the
            brushing for electrode regeneration in addition to conventional   counter electrode clean by automatically brushing away adhering
            reversed discharge. Naturally, the convenient reversed discharge is   sample deposits. The attached automatic sample retainer   Energy-Saving Design to Reduce Running Cost
            also provided as standard.                         mechanism allows everyone to set samples under identical
                                                                                                                                      While the instrument is not in analysis mode, argon gas flow is   Energy-saving design contributes lower running cost.
            To enhance long-term stability, the optional automatic   conditions.
                                                                                                                                      reduced to one-tenth compared with conventional model.



                                                                                                                                                                                                                         PDA-7000 Series
      4                                                                                                                                                                                                                     Optical Emission Spectrometer  5
   1   2   3   4   5   6   7   8   9