Page 6 - Shimadzu Nexera Series
P. 6

A New Benchmark of Intelligence


            Maximizing Reliability, Minimizing Down Time




























            Fully Unattended Operation from Startup to Shutdown
                                                                                                           Shutdown
            The Nexera can be set to start up at a specified time, so that it can complete
            auto-purge, equilibration and baseline checks in advance, and be ready for
                                                                                                 Checking results
            analysis as soon as you arrive at the lab. Moreover, the system can be set up in
            advance to run without user intervention all the way from startup through
                                                                                                              Analysis
            analysis to shutdown.
                                                                                                              complete
              You can view the status and predicted analysis completion time for multiple
            systems from any location via a smart device. None of these features requires any
            special software.
                                                                                 Auto-
                                                                              Diagnostics
                                                                                                         Analysis
            Auto-Diagnostics and Recovery

            In rare cases, air bubbles can form in the mobile phase and cause problems if inhaled into
            the pump. The Nexera has the ability to monitor baseline changes and pressure
            fluctuations to check for abnormalities.
              When it detects an unusual fluctuation, it can automatically pause the analysis, purge
            the flow path, and restart analysis once it has confirmed recovery to normal pressure.



                                            Pressure                                                        Analysis begins
              Auto-Diagnostics for Trapped
              Bubbles (Patent Pending)
                                                            Fluctuation detected
              If an air bubble becomes trapped in the
              pump head, it causes an abrupt drop in
                                                      Normal analysis                 Resume analysis
              pressure, after which periodic pressure                      Auto-purge  once stable
              changes (pulsations) will occur. This can
              be detected using Shimadzu’s
              proprietary bubble detection algorithm
              which assesses these distinctive
              pressure fluctuations caused by trapped
                                                     Sample 1    Sample 2                Sample 2
              bubbles to distinguish them from any               (Failure)               (Retry)
              expected changes in pressure.





      6
   1   2   3   4   5   6   7   8   9   10   11