Page 5 - Shimadzu Nexera Series
P. 5

Mobile Phase Monitor MPM-40


                                    Reservoir tray weight sensors monitor the remaining mobile phase in real time. P. 7


                                   System Controller SCL-40, CBM-40
                                    Supports remote monitoring via a smart device.
                                    Mobile phases can be purged and baselines checked easily via the touch panel.


                                   UV-VIS Absorbance Detector SPD-40 / SPD-40V
                                   Photodiode Array Detector SPD-M40

                                    Temperature control improves performance stability. P. 13
                                    Analytical data is linked to information about consumables to ensure traceability.


                                   Solvent Delivery Unit LC-40 Series

                                    Auto-diagnostics to detect problems during analysis, and an auto-recovery function. P. 6
                                    Reduces space requirements with a dual solvent delivery system. P. 12


                                   Autosampler SIL-40 Series

                                   PLATE CHANGER

                                    The injection speed is twice as fast as previous models, shortening multi-analyte
                                    processing times. P. 10
                                    Can perform continuous analysis on up to 44 microtiter plates.  P. 11
                                    High reproducibility and ultra-low carryover for micro-volume injections. P. 13
                                    Automated sample preparation functions such as diluting samples, adding internal
                                    standards, and performing derivatization reactions, reduce labor.


                                   Column Oven CTO-40 Series

                                    Slim-type column oven with half the width of the previous model.  P. 12
                                                                                       ™
                                    Easy column attach/detach mechanism prevents peak broadening. (Nexlock )
                                    Automatic management of column information such as number of injections and pressure
                                    during analysis.
                                    Monitoring of column degradation through usage history (when used with LabSolutions ).
                                                                                                ™