Page 7 - Shimadzu LCMS-9030
P. 7
Simple Design Ionization Units LabSolutions LCMS Software
™
A Simple Analytical Platform
In addition to the standard ESI ionization unit, optional APCI and Dual Ion Source (DUIS) probes are available for the LCMS-9030 LabSolutions LCMS is your single point of control for UHPLC of the LCMS-9030 are MS, SIM, MS/MS, MRM, MSMS and
to meet various analytical needs. Shimadzu's DUIS offers an ef cient combination of ESI and APCI ionization capabilities. and mass spectrometry data acquisition and data analysis. (DDA*). Three of these modes, MS/MS, MRM, and MS/MS
Intuitive icons and a common user interface with Shimadzu's (DDA), allow the user to fully customize settings such as
™
ESI (standard) APCI (optional) DUIS (optional) quantitative LCMS platform make accurate mass data analysis quadrupole isolation resolution. Users will nd easy yet
with the LCMS-9030 easy to perform. Qualitative and exible work ows with the LCMS-9030 Q-TOF.
The dual ion source continuously performs both electrospray
ionization (ESI) and atmospheric pressure chemical ionization quantitative acquisition modes that fully utilize the capability
(APCI).
* DDA: Data Dependent Acquisition
Time-Saving and Stress-Free
All ionization units are designed to be cable-free and
tube-free. The probe can be detached simply by unlocking and
lifting up on the unit. Switching between different ionization
Together with the Power of Shimadzu LC
sources is easy, and takes just seconds.
Shimadzu's renowned HPLC and UHPLC systems are the perfect the rapid cycle times of Shimadzu's sample injectors. In
chromatographic accompaniment to the LCMS-9030's high addition to reproducible high-throughput analysis, Shimadzu's
resolution and mass accuracy. LabSolutions software provides a UHPLC systems offer innovative method development tools
uni ed point of control from which data quality is enhanced (Method Scouting) and unique autosampler robotic functions
by the unmatched solvent delivery of Shimadzu's pumps and to enhance your analysis and expand your capabilities.
Nexera X2 i-Series Plus
™
Calibrant Delivery System (CDS) Sample
By incorporating this CDS, calibration standards can now be
introduced via a separate ionization probe that functions
independently from the main probe. This optional
sub-ionization unit is installed in the main probe housing and
is available for all probe types (ESI/DUIS/APCI). By having two
Main Probe
probes in one system, high-concentration calibration standards
can be introduced only when needed without switching ow Sub-Probe
Calibration
lines, and are kept in isolation from the sample stream, Standard
eliminating contamination.
Instrument Front
Sub-Interface
Ionization Unit Brochure (C196-E079) Brochure (C196-E091)
LCMS-9030
6 Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer 7