Page 7 - Shimadzu LCMS-9030
P. 7

Simple Design Ionization Units  LabSolutions  LCMS Software
                                       ™
            A Simple Analytical Platform



 In addition to the standard ESI ionization unit, optional APCI and Dual Ion Source (DUIS) probes are available for the LCMS-9030   LabSolutions LCMS is your single point of control for UHPLC   of the LCMS-9030 are MS, SIM, MS/MS, MRM, MSMS and
 to meet various analytical needs. Shimadzu's DUIS offers an ef cient combination of ESI and APCI ionization capabilities.  and mass spectrometry data acquisition and data analysis.   (DDA*). Three of these modes, MS/MS, MRM, and MS/MS
            Intuitive icons and a common user interface with Shimadzu's   (DDA), allow the user to fully customize settings such as
 ™
 ESI (standard)  APCI (optional)  DUIS  (optional)  quantitative LCMS platform make accurate mass data analysis   quadrupole isolation resolution. Users will  nd easy yet
            with the LCMS-9030 easy to perform. Qualitative and    exible work ows with the LCMS-9030 Q-TOF.
 The dual ion source continuously performs both electrospray
 ionization (ESI) and atmospheric pressure chemical ionization   quantitative acquisition modes that fully utilize the capability
 (APCI).
            * DDA: Data Dependent Acquisition



















 Time-Saving and Stress-Free

 All ionization units are designed to be cable-free and
 tube-free. The probe can be detached simply by unlocking and
 lifting up on the unit. Switching between different ionization
            Together with the Power of Shimadzu LC
 sources is easy, and takes just seconds.


            Shimadzu's renowned HPLC and UHPLC systems are the perfect   the rapid cycle times of Shimadzu's sample injectors. In
            chromatographic accompaniment to the LCMS-9030's high   addition to reproducible high-throughput analysis, Shimadzu's
            resolution and mass accuracy. LabSolutions software provides a   UHPLC systems offer innovative method development tools
            uni ed point of control from which data quality is enhanced   (Method Scouting) and unique autosampler robotic functions
            by the unmatched solvent delivery of Shimadzu's pumps and   to enhance your analysis and expand your capabilities.

            Nexera  X2                                         i-Series Plus
                    ™
 Calibrant Delivery System (CDS)  Sample

 By incorporating this CDS, calibration standards can now be
 introduced via a separate ionization probe that functions
 independently from the main probe. This optional
 sub-ionization unit is installed in the main probe housing and
 is available for all probe types (ESI/DUIS/APCI). By having two
 Main Probe
 probes in one system, high-concentration calibration standards
 can be introduced only when needed without switching  ow   Sub-Probe
 Calibration
 lines, and are kept in isolation from the sample stream,   Standard
 eliminating contamination.
 Instrument Front

 Sub-Interface
 Ionization Unit                                  Brochure (C196-E079)                               Brochure (C196-E091)

                                                                                                 LCMS-9030
 6                                                                                Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer  7