Page 6 - Shimadzu LCMS-9030
P. 6

Simple Design Ionization Units                                                                                            LabSolutions  LCMS Software
                                                                                                                                                                ™
                                                                                                                                      A Simple Analytical Platform



            In addition to the standard ESI ionization unit, optional APCI and Dual Ion Source (DUIS) probes are available for the LCMS-9030   LabSolutions LCMS is your single point of control for UHPLC   of the LCMS-9030 are MS, SIM, MS/MS, MRM, MSMS and
            to meet various analytical needs. Shimadzu's DUIS offers an ef cient combination of ESI and APCI ionization capabilities.  and mass spectrometry data acquisition and data analysis.   (DDA*). Three of these modes, MS/MS, MRM, and MS/MS
                                                                                                                                      Intuitive icons and a common user interface with Shimadzu's   (DDA), allow the user to fully customize settings such as
                                                                                     ™
            ESI (standard)                    APCI (optional)                   DUIS  (optional)                                      quantitative LCMS platform make accurate mass data analysis   quadrupole isolation resolution. Users will  nd easy yet
                                                                                                                                      with the LCMS-9030 easy to perform. Qualitative and    exible work ows with the LCMS-9030 Q-TOF.
                                                                                The dual ion source continuously performs both electrospray
                                                                                ionization (ESI) and atmospheric pressure chemical ionization   quantitative acquisition modes that fully utilize the capability
                                                                                (APCI).
                                                                                                                                      * DDA: Data Dependent Acquisition



















              Time-Saving and Stress-Free

            All ionization units are designed to be cable-free and
            tube-free. The probe can be detached simply by unlocking and
            lifting up on the unit. Switching between different ionization
                                                                                                                                      Together with the Power of Shimadzu LC
            sources is easy, and takes just seconds.


                                                                                                                                      Shimadzu's renowned HPLC and UHPLC systems are the perfect   the rapid cycle times of Shimadzu's sample injectors. In
                                                                                                                                      chromatographic accompaniment to the LCMS-9030's high   addition to reproducible high-throughput analysis, Shimadzu's
                                                                                                                                      resolution and mass accuracy. LabSolutions software provides a   UHPLC systems offer innovative method development tools
                                                                                                                                      uni ed point of control from which data quality is enhanced   (Method Scouting) and unique autosampler robotic functions
                                                                                                                                      by the unmatched solvent delivery of Shimadzu's pumps and   to enhance your analysis and expand your capabilities.

                                                                                                                                      Nexera  X2                                         i-Series Plus
                                                                                                                                              ™
              Calibrant Delivery System (CDS)                                        Sample

            By incorporating this CDS, calibration standards can now be
            introduced via a separate ionization probe that functions
            independently from the main probe. This optional
            sub-ionization unit is installed in the main probe housing and
            is available for all probe types (ESI/DUIS/APCI). By having two
                                                                                                      Main Probe
            probes in one system, high-concentration calibration standards
            can be introduced only when needed without switching  ow                                  Sub-Probe
                                                                 Calibration
            lines, and are kept in isolation from the sample stream,   Standard
            eliminating contamination.
                                                                                                     Instrument Front

                                                                 Sub-Interface
                                                                                  Ionization Unit                                                                          Brochure (C196-E079)                                Brochure (C196-E091)

                                                                                                                                                                                                                           LCMS-9030