Page 7 - Shimadzu LC-2030C NT
P. 7

Wavelength range                                  190 to 800 nm
                  Spectral resolution                          1.4 nm (Specified condition)
                  Slit width                                         1.2 nm, 8 nm
                  Device resolution                                  0.6 nm/pixel
                                                                        1024
                  Number of photodiode array elements                  ≤ ±1 nm
                  Wavelength accuracy
                 PDA Detector  Noise level        ≤ 500 × 10  AU/h (250 nm, reference: 350 nm, Specified conditions)
                                                   ≤ ±3 × 10  AU (250 nm, reference: 350 nm, Specified conditions)
                                                         −6
                                                         −6
                  Drift
                  Linearity
                                                                     Up to 100 Hz
                  Sampling rate                                     Up to 2 AU (5%)
                  Light source                      Deuterium (D2) lamp (Standard), tungsten (W) lamp (option)
                  Flow cell                                      8 µL (10mm, TC) 12 MPa
                                                              Conventional: 10 µL (10 mm, TC),
                  Option cell
                                                                Semi-micro: 2.5 µL (5 mm, TC)
                  Dimensions                                    W 410 × H 605 × D 500 mm
                                                                       67 kg
                  Weight                                               1 to 13
                 Miscellaneous  Materials for parts  Stainless steel (SUS316L, SUS316), FEP, PEEK, PTFE, perfluoroelastomer, ruby,
                  Available pH range
                                                       sapphire, Hastelloy  C, GFP, ceramic, PFA, quartz, PPS
                  in contact with liquids
                                                                    ®
                                                            LabSolutions  LC/GC Ver. 5.92 or later,
                                                                     ™
                  Workstation
                                                                                                  ™
                                                LabSolutions DB/CS Ver. 6.82 SP1 or later (Incompatible with LCsolution )



               Column


               Shim-pack NT-ODS is a silica-based monolithic column with both   Methyl Benzoate
               macropore (µm) and mesopore (nm) structure. The macropore
               structure helps to avoid column clogging, resulting in long-term
               stability.                                             Uracil        Toluene  Naphthalene











                      Macropore             Mesopore
                                                              0.0  0.5  1.0  1.5  2.0  2.5  3.0  3.5  4.0  4.5  min
                      SEM photograph of Monolith used for the column
               The well-designed chemical structure of the stationary phase provides
               superior reproducibility.










                                                                                                                   7
   2   3   4   5   6   7   8