Page 3 - Shimadzu GCMS-QP2010 SE
P. 3

Simple operation



                 The GCMS-QP2010 SE ...
                 Offers both the easy operation of the GCMS-QP2010 Series models as well as versatile functionality
                 Offers more than just high performance
                 Enables anyone to easily acquire highly reliable data
                 Features user-friendly operation and easy maintenance





               ˙   Easy Maintenance Reduces Downtime
               Design Offers the Ultimate in Ease of Use

               The GCMS-QP2010 SE incorporates a front-opening chamber in a design that is
               both visually pleasing and practical, allowing maintenance to be performed with
               ease from the front of the instrument. "MSNAVIGATOR," which supports
               maintenance, has been improved to help the user perform instrument
               maintenance.
                                                            Ion source
                                                                               The line of sight of a flat architecture
                                                                               makes the filament difficult to see.
                    Common Consumables

                 The same septa, vials, and other
                 consumables are universally used
                                                Pursuing a design with
                 across the QP2010 and QP5000 series
                                                ease of maintenance
                 systems.                       in mind.





               Easy sTop for Major Reduction of Maintenance Time
               Many applications require that the injection port undergoes maintenance on a
               frequent basis. With the GCMS-QP2010 SE, maintenance is possible without venting
               the MS so downtime is minimized.
                     Maintenance start
               Conventional                  Inlet heating
               procedure        Maintenance
                            Vacuum              Vacuum startup,
                 Inlet cooling                                     Analysis
                            stopped      Attainment of maximum vacuum level, Stabilization,
                             5 min  10 min        180 min
               Easy sTop    Maintenance
                 Inlet cooling    Inlet heating  Analysis
                             10 min  15 min
                                              Time savings of 3 hours









               The Easy sTop navigator assists in taking the appropriate steps.
   1   2   3   4   5   6