Page 4 - Shimadzu CELL PICKER
P. 4

Achieves Picking Results Comparable to Manual Processing





            Do you have problems with the dif cult and unstable procedures during the picking process?
            By automating cell collection, seeding, and pipette tip replacement, CELL PICKER stabilizes the operations of picking up and
            removing cell colonies, processes typically reliant on an operator's skill level. Using the easy-to-operate software, images of the
            cells can be automatically obtained before and after collection.





                                Search colonies          Targeting          Collection                                          Seeding                                              Work Records
           Manual Operation
                              ɾ 5IF DVMUJWBUJPO WFTTFM JT NPWFE             5IF  VTFS  PQFSBUFT  UIF  QJQFUUFS                  5IF  VTFS  PQFOT  UIF  MJE  PG  UIF  TFFEJOH
                              ɾ 5IF VTFS TFBSDIFT VOEFS UIF NJDSPTDPQF      VOEFS UIF NJDSPTDPQF  SFQFBUFEMZ                    WFTTFM  BOE  QSPDFFET  XJUI  TFFEJOH
                                GPS UIF DFMM DPMPOJFT UP CF DPMMFDUFE  BOE   QJDLJOH  VQ  UIF  NBSLFE  DPMPOJFT                 FOTVSJOH UIBU UIF DPSSFDU XFMMT BSF VTFE
                                UIFO NBSLT UIFN XJUI B QFO                  XIJMF SFQMBDJOH UIF QJQFUUF UJQ GPS   5JQ PG UIF QJQFUUF UJQ
                                                                            FBDI DPMPOZ

                                                                                    &YBNQMF PG B NJDSPTDPQF TDSFFO

                                                                                                                                                                                           /P SFDPSE JT LFQU PG XIBU DFMM DPMPOJFT XFSF DPMMFDUFE
                                  .BSLJOH UIF CBDL PG UIF WFTTFM XIJMF MPPLJOH UISPVHI   )BOE USFNPST NBLF QPTJUJPO BEKVTUNFOUT EJ⒏DVMU  MFBEJOH UP JOTUBCJMJUZ                            /P SFDPSE JT LFQU PG XIBU DFMM DPMPOJFT XFSF DPMMFDUFE
                                  UIF NJDSPTDPQF JT EJ⒏DVMU                     5IF QSPDFTT UBLFT B MPOH UJNF UP NBTUFS
                                  $BQUVSJOH JNBHFT POF BGUFS UIF PUIFS JT EJ⒏DVMU   8PSLJOH XIJMF MPPLJOH UISPVHI B NJDSPTDPQF GPS BO FYUFOEFE UJNF MFBET UP GBUJHVF






             CELL PICKER
                                Search colonies          Targeting          Collection                                          Seeding                                              Work Records
                 ʴ
                              ɾ 5IF DVMUJWBUJPO WFTTFM JT NPWFE             "O JNBHF DBO CF DBQUVSFE BVUPNBUJDBMMZ CFGPSF BOE BGUFS DPMMFDUJPO     ɾ 5IF  TFFEJOH  MPDBUJPO  NPWFT  BOE  UIF  DPMMFDUFE  DFMMT  BSF   *NBHFT DBO BMTP CF DBQUVSFE  TP SFDPSET PG XIJDI DFMM DPMPOJFT XFSF DPMMFDUFE
            AUTO CHANGER                                                                                                          BVUPNBUJDBMMZ TFFEFE                               DBO CF DIFDLFE
                              ɾ 6TJOH UIF TPGUXBSF  UIF DFMM DPMPOJFT UP CF DPMMFDUFE BSF GPVOE
                                BOE UIF PQFSBUJOH DPOEJUJPOT  NFUIPET  BSF TFMFDUFE                                             ɾ 5IF VTFE UJQ JT EJTDBSEFE















                                                                                   Stable Operations                                    Error Prevention        AUTO CHANGER
                                                                              $FMMT  DBO  CF  DPMMFDUFE  XJUIPVU  SFMZJOH  PO  BO   5IF XSPOH XFMMT BSF OFWFS TFFEFE                                                   Note: These images are for
                                                                              PQFSBUPS T TLJMM MFWFM                                                                                                                      illustrative purposes only.


                                                                                   Simple Operations                                                                                        Obtaining Seeding Records        AUTO CHANGER

                                                                              5P PQFSBUF  KVTU UBQ UIF CVUUPOT XIJMF WJFXJOH UIF                                                      5IF TFFEFE XFMM OVNCFST DBO CF BVUPNBUJDBMMZ BTTPDJBUFE XJUI
                                                                              JNBHF JO UIF NJDSPTDPQF XJOEPX                                                                          JNBHFT PG UIF DFMMT DPMMFDUFE

                                         Operation Window
                                                                                                                                                                                          Note:  AUTO CHANGER  This logo indicates a feature of systems equipped with AUTO CHANGER.

                                                                                                                                                                                                                         CELL PICKER
      4                                                                                                                                                                                                             Automated Picking and Collecting of Cell Colonies  5
   1   2   3   4   5   6   7   8   9