Recently, natural gas has been recognized as a clean resournce for energy, in addition to being a raw material for chemical products. Recently a cutting-edge drilling technology has increased the use of shale gas. As the production area diversifies, the need for gas composition analysis has increased. Shimadzu addresses analytical requests with a wide system GC lineup. For analysis of liquified gas, such as LPG, a dedicated injector with a vaporizer is available. Both manual injection and online injection are available. The operation software can automatically calculate needed values, such as indexes, calorific values, etc.

The ultrafast natural gas analyzer UFRGA

Natural Gas Analysis System Lineup


Model Name
Nexis GC-2030 BIDUFNGANexis GC-2030FNGA-II1Nexis GC-2030FNGA-II2Nexis GC-2030FNGA1Nexis GC-2030FNGA2
Reference MethodASTM-D1945, ASTM-D3588, GPA-2261ASTM-D1945, ASTM-D3588, GPA-2261ASTM-D1945, ASTM-D3588, GPA-2261ASTM-D1945, ASTM-D3588, GPA-2261ASTM-D1945, ASTM-D3588, GPA-2261
Type of DetectorBID, FIDTCDx2, FIDTCD, FIDTCDx2, FIDTCD, FID
Target CompoundsPermanent gases, C1-C5, H2S, C6+(backflush)H2, O2, N2, CO, CO2, H2S, C1-C5, C6+(backflush)O2, N2, CO, CO2, H2S, C1-C5, C6+(backflush)He, H2, O2, N2, CO, CO2, H2S, C1-C5, C6+  (backflush)O2, N2, CO, CO2, H2S, C1-C5, C6+ (backflush)
Analysis Time5 minutes10 minutes10 minutes10 minutes10 minutes
OthersPermanent gases>10 ppm,
H2S>100 ppm,
CH4>100 ppm, Other hydrocarbons>10 ppm,
Calorific value software available
Permanent gases>100 ppm,
H2S>1000 ppm,
CH4>20%, Other hydrocarbons>10 ppm,
Calorific value software available
Permanent gases> 100 ppm,
H2S>1000 ppm,
CH4>20%, Other hydrocarbons>10 ppm,
Calorific value software available
Permanent gases>50 ppm,
H2S>500 ppm,
Hydrocarbons>10 ppm,
Calorific value software available
Permanent gases>50 ppm,
H2S>500 ppm,
Hydrocarbons>10 ppm,
Calorific value software available
Application Datasheet
Download

Download

Download

Download

Download
Model NameNexis GC-2030ENGA1Nexis GC-2030ENGA2Nexis GC-2030NGA1Nexis GC-2030NGA2Nexis GC-2030HNR1Nexis GC-2030HNR2
Reference MethodASTM-D1945, ASTM-D3588, GPA-2261ASTM-D1945, ASTM-D3588, GPA-2261ASTM-D1945, ASTM-D3588, GPA-2261ASTM-D1945, ASTM-D3588
Type of DetectorTCDx2, FIDTCDx2, FIDTCDTCDFIDFID
Target CompoundsHe, H2, O2, N2, CO, CO2, H2S, C1-C14H2, O2, N2, CO, CO2, H2S, C1-C18He, H2, O2, N2, CO, CO2, H2S, C1-C5
(Better He and  H2 sepration)
O2, N2, CO, CO2, H2S, C1-C5, C6+(backflush)C1-C5 C6+(backflush)C1-C5 C6+(backflush)
Analysis Time30 minutes28 minutes23 minutes23 minutes27 minutes10 minutes
OthersPermanent gases>50 ppm,
H2S>500 ppm,
Hydrocarbons>10 ppm,
Liquified samples can be directly injected.
Permanent gases>50 ppm,
H2S>500 ppm,
Hydrocarbons>10 ppm,
Liquified samples can be directly injected.
C1 is 0.01%,C2-C6 is 0.001% Packed column as main columnHydrocarbons > 0.001% Good separation
Application Datasheet
Download

Download

Download

Download

Download

Download

ISO6974-3

ISO6974-4

Compliant systems are also available.

LPG Analysis System Lineup

Model NameNexis GC-2030LPGHC1Nexis GC-2030LPGHC2Nexis GC-2030DFC1
Type of DetectorFIDFIDFID x2
Target Compounds10 ppm for hydrocarbon C1-C610 ppm for hydrocarbon C1-C60.1 ppm to 90% for C1-C5,
0.1 ppm to 10% for Methanol,
0.1 ppm to 10% for Ethanol
Analysis Time15 minutes15 minutes11 minutes
OthersLPG is vaporized by on-line vaporizer device.Liquid sample is measured by internal sample loop in the liquid sampling device.Analysis of methanol and ethanol in LPG
Application Datasheet
Download

Download

Download

GC-2014 system is also available for some applications.