Page 5 - Hydrocarbon-Solution HC Processing
P. 5
Shimadzu Customized GC Analyzers Trace Sulfur Analysis GC System VUV PIONA+ Analysis GC System
Sulfur Chemiluminescence Detection Gas Chromatograph System
• Comprehensive gasoline measurements determining bulk
SCD-2030 PIONA and specific oxygenate and BTEX compound
Various Applications in the HPI Market content.
• Best-in-Class Sensitivity • Provides a lot of information in a fast, robust measurement.
• Unmatched Stability performance
• Support third-party detectors, including a pulsed flame • Relatively simple instrumentation, setup, and analysis
photometric detector (PFPD) and a pulsed discharge helium • Excellent Maintainability procedures.
ionization detector (PDHID). • Automation Functions
• Support third-party software for detailed hydrocarbon analysis 1.3
(DHA) and Chrom Merge. 1.2
• Support liquefied petroleum gas (LPG) sampling devices and 1.1
vaporizers. Relative Response Factor 1.0
• Complete application manual and methods 0.9 1-Butanethiol b.p. 98℃
Methyl disulfide b.p. 109℃
0.8
Diethyl disulfide b.p. 152℃
0.7 3-Methylbenzothiophene b.p. 273℃
Nexis GC-2030 0 50 100 150 200 250 300 350 400
Analysis time (Hours) (Day 16)
VUV Chromatogram of Gasoline Sample
Excellent Long-Term Stability
* The VUV detector VGA-100 is a product of VUV
Product Lineup ANALYTICS, INC.
Natural Gas Analyzers Refinery Gas Analyzer Process and Custom TOGA/DGA Analyzer Petrochemicals Simulated DHA Analyzers Oxygenates Analyzers Sulfur Analyzers Aromatics Analyzers
(RGA) Gas Analyzers analyzer Distillation
ASTM D1945/D1946 UOP 539, ASTM D7833, ASTM D1946 ASTM D3612C ASTM ASTM D7096, ASTM D5134, D6729, ASTM D4815,D7423 ASTM D6228 ASTM D3606, 5580
GPA 2261, GPA 2177 D 2163 ASTM E1746 D6228 D7213, D3710, D6730, D6733, D8071 UOP 960 ASTM D5504
Applicable GPA 2286, GPA 2186 D2887, D6417, ASTM D5623
D6352, D7500,
Methods ISO 6975 D5307, D7169, ASTM D7011
IP 480, ISO3924
C1-C6+ Hydrocarbons, C1-C6+ Hydrocarbons O2, N2, CO, CO2 TOGA with Head Space Trace Sulfur Boiling Point C1-C14 Hydrocarbons C1-C4 Alcohols Trace Sulfur Analysis Aromatics
Non Condensable gases saturates and unsaturates Impurities in Chlorine H2, O2, N2, CO, CO2, C1, Distribution PIONA Report Individual components
O2, N2, CO, CO2 and H2S H2S, Non Condensable C2's, C3's C1-C110 (As per
Analysis Optional Hydrogen gases O2, N2, CO, CO2 method)
Extended NGA C1-C14+ and H2
NGL, Dual Oven NGA LPG Sampling
High Speed NGA Vaporizer
Analysis time 10 min. Analysis time less than Special Hastelloy High Sensitivity PFPD for Sulfur Fast Simdist Tuned D6730 column Use of N2 Carrier for Use of FPD, PFPD or SCD Combination model for
6 min. Material for Chlorine Extension up to C4 Correlations with Fast DHA D4815 Detectors D3606, D5580. D4815
Analyzer D86 and D1160,
Features Front End PIONA
Integrated Room Temperature
Shimadzu
Software Database
VUV PIONA+
Transformer Oil Gas Analyzer (TOGA) Simulated Distillation Analyzer Trace Moisture Analysis GC System
uV BID
• Easily analyzes both liquid and gas 15000 LPG(Main) Water 25 ppm,
RT= 14.3 min, S/N=350+
samples 12500
TM
• Uses a variety of Watercol GC columns 10000
depending on the matrices 7500
• Uses a simple, high-sensitivity, and very 5000
stable low-cost Barrier Ionization 2500
Discharge (BID) Detector 0
2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 min
Note: With baseline subtraction
Analysis of Water in LPG
Shimadzu's Total Solutions for the Hydrocarbon Processing Industry
4 Analytical and Testing Instruments for the HPI Market 5