Page 3 - Shimadzu Hydrocarbon Processing
P. 3

Various Applica�ons in the Hydrocarbon Processing Industry

















                 GC-2014                        Nexis GC-2030                                  GC-2010 Plus


 Natural Gas   Refinery Gas Analyzer   Green House Gas   TOGAS Analyzer  TOGAS w/ BID Analyzer  Simulated Distillation  DHA/PIONA Analyzers  GPC Analyzer  Aromatics Analyzers  Oxygenates in Gasoline




 Analyzers *  (RGA) **  Analyzers                                                                Analyzer

 Application Methods  ASTM D1945/D1946,   UOP 539, ASTM D7833,   ASTM D3612A,B & C***  ASTM D3612A,B & C***  ASTM D2887, ASTM D3710,   ASTM D6729, ASTM D6730  ASTM D6474, D6579, D5296  ASTM-D3606, ASTM-D5580  ASTM-D4815
 GPA 2261, GPA 2177,   D3588, D1945, D1946  ASTM D5307, ASTM D6352,
 GPA 2286, GPA 2186  ASTM D6417, ASTM D7096,
  ASTM D7169, ASTM D7213,
  and ASTM D7500.
 Analysis  Air/Nitrogen, Methane,  C1-C6+ saturates and   N2O, CO2 and CH4 in   Accurate measurement   O2, N2, CH4, CO are   C6 to C44 alkane  Single-column application   Molecular Weuight distribution  Using D3606, dedicated to the   Individual ethers are determined







 CO2, Ethane, Propane,   unstarurates, H2S,Non-  atmospheric air. This   of dissolved gases which   separated and detected   for the separation and   of polymers which separates   separation and quantification   from 0.1 to 20.0 as %. Individual

 I-Butane, N-Butane,   Condfensabvle gases,   system will also separate   include H2, O2, N2, CH4,   by BID; CO2, C2H2, C2H4,   identification of six main   molecules by size.  of benzene and toluene in   alcohols are determined from 0.1



 Neo-Pentane,   O2,N2,CO & H2, LPG   and provide quantitative   CO, CO2, C2H6, C2H4, and   C2H6 and C3H6 detected by   compound classes in spark   finished gasoline. Benzene can   to 12.0 mass %.




 I-Pentane, N-Pentane   sampling, Vaporizer  information for N2,   C2H2 in mineral spirit based  FID. CO2 passes through a   ignition fuel samples:   be determined between the


 and Hexanes+ by   O2 and CO. *SF6 can   transformer oil via direct   Methanizer and is reduced to   paraffins, Isoparaffins, olefins,   levels of 0.1 and 5 volume %



 backflush  be added per special   injection and oil stripper   CH4, which, is combustible   naphthalenes, aromatics, and   and toluene can be determined





 request. The run time can  extracti on  and analyzed by FID.  oxygenates.  between the levels of 2 and 20
 be extended to include                                            volume %. Ethanol co-elution

 ethane, othylene and                                              is managed by using a special
 acetylene in the analysis.                                        proprietary column set.



 Features  • Turnkey systems  • Automatic Refinery Gas   • Includes 3 detectors and  • Off er all three methods  • TCD replaced by very  • Support all official SimDist   • Simple single-column   • Stable detector  • 10 minute fast analysis time  • Rugged configuration






 • Fully configured     BTU report     a methanizer  • High sensitivity     sensitive  BID     methods     method  • Easy-to-use GPC software  • Complete turnkey systems  • Economical


 • Customizable systems • 6 minute fast analysis   • Low-level analysis  • Extension up to C4  • Hydrogen & methane   • Simdist software fully   • All recommended    • Customizeable report layout

 • Automatic BTU      time  • 15 minute fast analysis   • Choice of 2 headspace     sensitivity down to 100ppb     integrated into LabSolutions      consumables included  • Fully integrated HPLC system






    reports  • Four simultaneous      time     models  • Turnkey system  • Simple automated operation  • Room temperature method


    injections  • Distillation curve overlay


  • Distillation reports and

     curve data can be easily
     exported as ASCII data to
     Excel
  • Results correlated to D86 or
     D1160
        Shimadzu BID Detector                                          Shimadzu Simdist System

        High Sensi�vity

        Detection sensitivity over 100x higher than

        TCD, 2x higher than FID
        Novel Universal Detector
        Single-detector approach for your complex
        analyses
        Long-Term Stability
        Long-term stability with
        new discharge design
   1   2   3   4   5   6   7   8