Page 4 - XDimensus300
P. 4

High Accuracy








                 The XDimensus 300 provides the highest level of sphere distance
                 accuracy, with a measurement error of (3.8 + L/50)*  m.
                                                                                                                                                                               Operating camera

                 In addition to Shimadzu's proprietary microfocus X-ray generator and a detector with high resolu-
                 tion and a wide field of view, it is equipped with an air conditioning unit to maintain a constant
                 temperature inside the instrument, a granite frame that provides high geometric stability, and an
                 ultra-high-accuracy sample positioning stage, thereby achieving highly accurate measurements.
                                                                                                                                                                                                                           X-ray detector
                 * Example: A 5.8  m error for L = 100 mm
                                                                                                                                                X-ray tube

                  Proprietary Microfocus 225 kV Generator

                   The system is equipped with a high output microfocus X-ray generator,
                   which generates 225 kV. X-ray focal point drift caused by heat is corrected
                   in real time.

                                                                                                                                               Operating camera                     CT stage
                  Self-Diagnostic Function

                   The system is equipped with a self-diagnostic function to monitor the
                   system status. The operator is notified of the system status in real time.





                  Shield Box Internal Temperature Control Device

                   The system is equipped with a temperature control system, which controls
                   the temperature inside the shield box. A thermostatic room is not required,
                   so it is not necessary to be as selective about the installation site.



                  Anti-Vibration Stands

                   The manipulator is installed on an anti-vibration stand. This suppresses                                                                                              Detector with High Resolution
                   vibrations from outside the system, reducing the impact on measurement                                                                                                and a Wide Field of View
                   accuracy.
                                                                                                                                                                                         A 16-inch high-resolution flat panel detector has been
                                                                                                                                                                                         adopted. It achieves both high resolution and a wide
                                                                                                                                          Ultra-High-Accuracy Rotating Stage             field of view.
                  Operating Cameras                                                                                                       Air bearings have been adopted for the rotating stage.

                   Two operating cameras monitor the inside on a real-time basis. Operators                                               A loading sample size of 300 mm in diameter and 300
                   can control the system interactively via a computer screen.                                                            mm in height has been achieved while minimizing
                                                                                                                                          problems with shaft eccentricity.


                                                                                                                                                                                                                     XDimensus 300
                                                                                                                                                                                                                             Dimensional X-Ray CT System
      4                                                                                                                                                                                                                                        5